535637
263
Zoom out
Zoom in
Previous page
1/294
Next page
Technical Specifications
Product Reference Guide
261
Table 39
Programming Mode
- The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
ming Mode Entry
A valid programming label has
been scanned
.
Green LED blinks continu-
ously
Reader sounds four low frequency
beeps.
Label Program-
ming Mode Rejec-
tion of Label
A label has been rejected.
N/A
Reader sounds three times at low-
est frequency & current volume.
Label Program-
ming Mode Accep-
tance of Partial
Label
In cases where multiple labels
mu
st be scann
ed to program one
feature, this indication acknowl-
edges each portion as it is success-
fully scanned.
N/A
Reader sounds one short beep at
highest frequenc
y & current vol-
ume.
Label Program-
ming Mode Accep-
tance of
P
r
ogramming
Configuration option(s) have been
succ
essfu
lly programmed via
labels and the reader has exited
Programming Mode.
N/A
Reader sounds one high frequency
b
eep and 4 low frequency beeps
followed by reset beeps.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has been scanned.
N/A
Reader sounds two times at low
fr
equenc
y and current volume.
. Programming Mode Indications
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has not passed its
automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.
NUMBER OF LED
FLASHES/BEEPS
ERROR CORRECTIVE ACTION
1 Configuration
Contact Helpdesk for assistance
2 Interface PCB
4 Reader Module
6 Digital PCB
14 CPLD/Code Mismatch
Green Spot
a
flashes momen-
tarily
Upon successful read of a label, the
software shall turn the green spot
on for the time specified by the
configured value.
N/A N/A
a. Except when in sleep mode or when a Good Read LED Duration other than 00 is selected
INDICATION DESCRIPTION LED BEEPER
263


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic Gryphon I GFS4100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic Gryphon I GFS4100 in the language / languages: English as an attachment in your email.

The manual is 14,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info