37609
4
Zoom out
Zoom in
Previous page
1/4
Next page
4
+ 1 HR
+ 2 HR
+ 3 HR
SETTING THE CLOCK
Press PROG to display the time of day (the display blinks). Press DAY
(the display stops blinking) to select today (1 = Monday, 6 = Saturday
etc).Press and hold down the + or - button to change the time quickly
in ten minute steps, or press and release to change the time by one
minute.
When the day and time are correct, press and release PROG once to
start the clock and further press and release as necessary until the
colon starts blinking, (RUN mode.) The intermediate stages are
explained in the Setting Instructions.
WINTER TIME / SUMMER TIME CLOCK
When the clocks are changed from Summer Time to Winter Time (or
vica versa) there is no need to alter the clock by entering programming
mode (i.e. pressing the PROG button). Instead just press and hold
down the - button to change from Summer Time to Winter Time or the
+ button to change from Winter Time to Summer Time. The first time
this is done (after a RESET) the clock is set and can only be changed
by one hour as appropriate.
If a mistake is made, e.g. pressing the + button in the autumn when the
- button should have been pressed, rectify the problem by pressing the
correct button and then re-setting the clock by one hour as appropriate.
(Refer to SETTING THE CLOCK above).
TIME OR TEMPERATURE DISPLAY
The default display in RUN mode shows the time of day. This may be
changed to display the actual temperature being sensed by pressing
both COPY and NEXT buttons together. Return to time display by
pressing them together again.
THERMOSTAT MODE
The TP75 may be converted to control at a constant, user selected,
temperature by pressing and holding down the s and t buttons until
the display changes to that shown in Fig. 6 with the default temperature
of 8°C (or 46°F), which may be changed as required using the s or t
button. The unit will stay in thermostat mode until the s and t are
pressed together again.
FROST THERMOSTAT MODE
Whilst in thermostat mode the TP75 may be set to guard against
possible frost damage in areas where the unit (or its remote sensor) is
fitted. The control temperature may be set to a suitable level using the
s or t buttons. The unit will stay in frost thermostat mode until the s
and t are pressed together again.
HOLIDAY MODE
Whilst in thermostat mode pressing the DAY button will activate the
holiday mode. The display will change to that shown in Fig. 7 with a
number indicating the default holiday period of 00 days. Use the s or
t buttons to adjust the control temperature as required, and use the
+ or - buttons to set the number of days required, in the range 1-99
days. If the number of days is left at 00 then the unit will return to normal
at event 1 the following day. When the selected number of days have
elapsed the unit will automatically return to normal, controlling
temperatures to the set programme.
Fig. 4. Clock time ready for
changing. (Colon steady,
digits blinking).
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 5.
Temperature Display.
(Room temperature is
below the set temperature,
so the boiler is firing)
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 6. Thermostat mode.
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 7.
Holiday mode.
HOLIDAY MODE Continued.
Control may also be restored to normal by pressing the s and t
together.
USER OVERRIDES
Whilst the unit is operating normally in RUN mode the following
overrides are available:
TEMPERATURE SETTING OVERRIDE
Press s to increase or t to decrease the current set temperature.
Each press will change the temperature setting by 0.5°C (or 1°F). To
make larger changes press the button and hold it down.
/ OVERRIDE
With (profiled) selected temperature control will follow the
programme.
With (allday) selected the temperature set for Event 1 will
be maintained until Event 6. During this "ALLDAY" period the
programmed temperature may be overriden as above.
+1 HR/+2 HR/+3 HR OVERRIDE
Pressing this button once causes the current control temperature to
last for an extra hour. Press it twice for an extra 2 hours, and three
times for 3 hours. Pressing a fourth time will remove the override.
For example, a comfort temperature of 21°C programmed to end at
22:30 could be extended passed midnight. Alternatively, a morning
set-back temperature of 15°C could be extended to effectively cancel
a midday comfort setting.
BATTERY MAINTENANCE
Only good quality alkaline batteries should be used.
New batteries will provide the power for switching the outputs on and
off for approximately 2 years. When the batteries volts fall to the
minimum level needed to maintain operation a battery symbol will blink
in the display. When this symbol appears both batteries should be
replaced with high quality alkaline cells. Operation will continue
normally until the 15th midnight after the symbol started blinking and
then the unit will switch off all outputs, and shut down with just the time
and the blinking battery displayed. Whilst the battery symbol is still
blinking, the old batteries may be removed and new batteries placed
in the sleeve provided and inserted within one minute. Internal
circuitry will maintain the user set programme memory during this
period.
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 8 Temperature
overridden - boiler firing.
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 9.
Allday selected - event 1
temperature active.
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 10.
Current temperature
extended by 2 hours.
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 11.
Blinking battery symbol,
change batteries.
Danfoss Randall Ltd. continually strives to improve its
products and reserves the right to change designs and
specifications without notice.
Part No: 8953 Iss 9 12/01
Danfoss Randall Limited
Ampthill Road
Bedford, MK42 9ER
Tel: (01234) 364621
Fax: (01234) 219705
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Danfoss TP75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Danfoss TP75 in the language / languages: English as an attachment in your email.

The manual is 0,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Danfoss TP75

Danfoss TP75 User Manual - German - 4 pages

Danfoss TP75 Installation Guide - Dutch - 4 pages

Danfoss TP75 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info