FACTORY PRE-SET PROGRAMME
The TP75 range of programmable room thermostats are provided with a factory pre-set
programme of switching times and temperatures, so that, once the clock has been set and the
TP75 returned to the RUN mode, the heating system will be controlled at the times and to the
temperatures of the pre-set programme, as shown in the following table and indicated by the
fine line in the diagram below.
The instructions on the previous page show how to change the times and temperatures to the
users requirements.
The table should be used to record the users programme. If the TP75 has been configured for
5/2 day control only days 1 and 6 need be recorded.
Factory Pre-set Programme, and spaces for user’s settings.
Day
Events
123456
Pre-set User’s Pre-set User’s Pre-set User’s Pre-set User’s Pre-set User’s Pre-set User’s
1
(Monday)
Time 06:30 08:30 11:30 13:30 16:30 22:30
°C201520152115
°F685968597059
2
(Tuesday)
Time 06:30 08:30 11:30 13:30 16:30 22:30
°C201520152115
°F685968597059
3
(Wednesday)
Time 06:30 08:30 11:30 13:30 16:30 22:30
°C201520152115
°F685968597059
4
(Thursday)
Time 06:30 08:30 11:30 13:30 16:30 22:30
°C201520152115
°F685968597059
5
(Friday)
Time 06:30 08:30 11:30 13:30 16:30 22:30
°C201520152115
°F685968597059
6
(Saturday)
Time 07:30 09:30 11:30 13:30 16:30 22:30
°C202020202115
°F685968597059
7
(Sunday)
Time 07:30 09:30 11:30 13:30 16:30 22:30
°C202020202115
°F685968597059
23°C
Event 1
Events
2, 3 & 4
Event 5
Event 6
22°C
21°C
5
6
20°C
1
2
3
4
19°C
18°C
17°C
16°C
Factory Pre-sets
15°C
User’s Settings
14°C
13°C
0:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 24:00
In the above diagram the heavy line indicates what a typical user-set programme might be. Note
that event 2 has been moved to 14:00, that events 3 & 4 have also been moved to that time,
and that the following control temperature will be that of event 4.
It is possible to move events past midnight into the following day, when the day number will blink
in the display, see the display diagram in the notes on setting event times.
NOTES ON SETTING EVENT TIMES
If, during the event checking and setting
procedure, no buttons are pressed for more
than two minutes then the TP75 will return to
RUN mode automatically. If this appears to
have occured, it is advisable to re-check the
programme to ensure that it is as required.
When setting event times and temperatures
it is not possible to set event times out of
chronological order.
Event 1 may be set at any time from 0:00 to
23:59 (but would normally be in the morning).
Event 2 may be set at any time between event
1 and 23 hours, 59 minutes after event 1.
Event 3 may be set at any time between event
2 and 23 hours, 59 minutes after event 1.
Event 4 may be set at any time between event
3 and 23 hours, 59 minutes after event 1,....
and so on.
If the event time being set is moved past
midnight into the following day then the
number of the following day will blink.
When using the + button to adjust events 1 to
5 and the event time being adjusted becomes
the same as the following event time, then
both are changed simultaneously. This applies
to all subsequent event times reached and is
demonstrated in the diagram on the left.
When using the - button to adjust events 2 to
6 and the previous event time is reached the
- button ceases to respond.
The factory pre-set programme may be
reinstated by pressing the recessed RESET
button. This will however reinstate all the
factory pre-set conditions, so that the clock
type, temperature scale and optimum start
period (if enabled) may also have to be re-set.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Danfoss TP75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Danfoss TP75 in the language / languages: English as an attachment in your email.

The manual is 0,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Danfoss TP75

Danfoss TP75 User Manual - German - 4 pages

Danfoss TP75 Installation Guide - Dutch - 4 pages

Danfoss TP75 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info