465413
82
Zoom out
Zoom in
Previous page
1/84
Next page
TP4000 Range
Electronic Programmable Room Thermostat
MAKING MODERN LIVING POSSIBLE
User Guide
Danfoss Heating
TP4000
2
TP4000 Range
Electronic programmable room thermostat
®
Certification Mark
For a large print version of these instructions
please call Marketing on 0845 121 7400.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other
printed material. All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Heating
3
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
G
B
F
R
E
E
E
S
S
S
NL
G
R
PL
CZ
T
R
HR
RO
LT
HR
RO
GB
FR
ES
NL
GR
PL
CZ
TR
Thank you for Buying a Danfoss Product
Merci d’avoir choisi les produits Danfoss
Gracias por adquirir productos Danfoss
Bedankt dat u een Danfoss product heeft gekocht
Σας ευχαριστούμε για την αγορά ενόςDanfoss προϊόντος
Dziękujemy za zakup produktu Danfoss
Děkujeme Vám za nákup výrobku fi rmy Danfoss
Danfoss Ürünlerini Kullandığınız İçinTeşekkür Ederiz
Zahvaljujemo na kupovini Danfoss proizvoda
Vă mulţumim că aţi cumpărat produse Danfoss
Köszönjük, hogy Danfoss terméket vásárolt!
Dėkojame, kad perkate Danfoss Produktus
HR
RO
HU
TP4000
4
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
GB
Index
1.0 Basics
1.1 Your programmable room thermostat .......................................6
1.2 Preset Programmes ...........................................................................6
1.3 Before you start...................................................................................6
1.4 Setting the Clock ................................................................................7
1.5 Running your programme ..............................................................7
2.0 Advanced
2.1 Before you change the preset programmes ............................7
2.2 Changing the preset programmes ..............................................8
2.3 Running your programme ..............................................................8
2.4 User Overrides .....................................................................................9
2.5 Altering display to show time or room temperature ............8
2.6 To temporarily alter current programmed temperature ........9
2.7 Frost Protection and Thermostat Mode .....................................9
2.8 Toggle between 12 hour and 24 hour clock ............................9
2.9 Toggle between °C and °F scaling ............................................. 10
3.0 Battery Replacement ............................................................................ 10
4.0 Resetting the unit ................................................................................... 10
User Instructions
TP4000 Range
Electronic Programmable Room Thermostat
Danfoss Heating
5
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
Danfoss Heating
GB
What is a programmable room thermostat?
... an explanation for householders
A programmable room thermostat is both a programmer and a room thermostat. A
programmer allows you to set ‘On and ‘Off time periods to suit your own lifestyle. A
room thermostat works by sensing the air temperature, switching on the heating when
the air temperature falls below the thermostat setting, and switching it off once this set
temperature has been reached.
So, a programmable room thermostat lets you choose what times you want the
heating to be on, and what temperature it should reach while it is on. It will allow you
to select diff erent temperatures in your home at diff erent times of the day (and days of
the week) to meet your particular needs.
Turning a programmable room thermostat to a higher setting will not make the room
heat up any faster. How quickly the room heats up depends on the design of the
heating system, for example, the size of boiler and radiators.
Neither does the setting aff ect how quickly the room cools down. Turning a
programmable room thermostat to a lower setting will result in the room being
controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to fi nd the lowest
temperature settings that you are comfortable with at the diff erent times you have
chosen, and then leave it alone to do its job. The best way to do this is to set low
temperatures fi rst, say 18°C, and then turn them up by one degree each day until
you are comfortable with the temperatures. You won’t have to adjust the thermostat
further. Any adjustments above these settings will waste energy and cost you more
money.
If your heating system is a boiler with radiators, there will usually be only one
programmable room thermostat to control the whole house. But you can have
diff erent temperatures in individual rooms by installing thermostatic radiator valves
(TRVs) on individual radiators. If you dont have TRVs, you should choose a temperature
that is reasonable for the whole ho use. If you do have TRVs, you can choose a slightly
higher setting to make sure that even the coldest room is comfortable, then prevent
any overheating in other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types have to be adjusted in spring
and autumn at the changes between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for example, ‘Override,
Advance or ‘Boost. These are explained in the manufacturers instructions.
Programmable room thermostats need a free fl ow of air to sense the temperature, so
they must not be covered by curtains or blocked by furniture. Nearby electric fi res,
televisions, wall or table lamps may prevent the thermostat from working properly.
TP4000
6
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
GB
1.0 Basics
1.1 Your programmable room thermostat
The TP4000 allows you to programme up to 6 times and temperatures
at which your heating will come on and go off each day.
It features several user overrides including frost protection,
thermostat mode and time or temperature display.
1.2 Preset Programmes
Your TP4000 comes ready programmed with a set of operating times
and temperatures which often suit most people.
If you want to change any of these settings you can do so by following
the instructions on page 8.
First, follow the steps on page 7 to set the correct time and date.
Event Time Temp °C
1 06:30 20
2 08:30 15
3 11:30 20
4 13:30 15
5 16:30 21
6 22:30 15
RESET
Open the fl ap on the front of the programmer
and press the RESET button with a non-
metallic object until the display goes blank.
This will ensure that the factory programmes
are set and that the micro-computer in the
product is operating correctly.
1.3 Before you start
Danfoss Heating
7
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
GB
1.4 Setting the Clock
Note: clock is displayed in 24 hour mode.
Press PROG and Λ until the time on the display
ashes.
Use + or - to adjust the TIME (press and hold to
change in 10 min increments).
Press PROG to enter the TIME.
1.5 Running your programme
If you are happy to use the preset programmes
on page 6, you don’t need to do anything else.
Your unit is now in RUN mode.
2.0 Advanced
2.1 Before you change the preset programmes
Please Note
The unit must be programmed in sequence. Event times cannot
be programmed out of sequence.
If you want to leave a preset time as it is, simply press PROG to
move on to the next setting.
During programming, if no buttons are pressed for 2 minutes the unit
will automatically return to RUN mode, and the programme set up to
that minute will be active.
TP4000
8
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
a) Press PROG until 1st pre-set time and
temperature appears in display.
b) Use + or – buttons to adjust the TIME
(press and hold to change in 10 min
increments).
c) Use Λ or V buttons to adjust the
TEMPERATURE.
d) Press PROG to move to next preset time &
temperature (Event 2).
e) Repeat steps b, c & d for programming
Events 3, 4, 5 & 6.
Note: Press and hold PROG at any time will
make the unit return to RUN mode.
2.3 Running your programme
Press PROG – the colon in the LCD display
will start to fl ash. The heating will now be
controlled with the programmed times and
temperatures.
2.4 User Overrides
Sometimes you may need to change the way you use your heating
temporarily, e.g. due to unusually cold weather. The TP4000 has several
user overrides, which can be selected without aff ecting the thermostat
programming.
GB
2.2 Changing the preset programmes
Danfoss Heating
9
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
GB
2.5 Altering display to show either time or
actual room temperature
· Press + and – together to change between
settings.
· Press Λ or V until required temperature is
displayed.
(This override will automatically cancel at
beginning of next programmed event).
2.6 To temporarily alter the current programmed
temperature
A constant temperature between 5°C-30°C can be selected if desired, for
example, for frost protection.
· Press Λ and V together.
· Use Λ or V buttons to set the desired low
temperature.
- At 5°C a snowfl ake symbol appears
indicating frost protection mode.
- At all other temperatures the snowfl ake
symbol is turned off .
· To return to automatic programming press
Λ and V together again.
2.7 Frost Protection and Thermostat Mode
To change time display between 12 hour and 24 hour clock. Press Λ
and + together to toggle between 12 and 24 hour clock.
2.8 Toggle between 12 hour and 24 hour clock
TP4000
10
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
GB
3.0 Battery Replacement
When batteries are low a battery symbol will
ash in the LCD display. You have 15 days to
replace the battery before the unit switches
off .
When changing batteries, remove old batteries and insert new ones
within one minute and programming will not be lost.
!
4.0 Resetting the unit
Partial reset: Press RESET (used to restart micro-computer) if display
freezes for any reason. This does not reset any programme, clock or
date. It is recommended that this is done at time of installation.
User full reset: Press RESET whilst holding down PROG button. This
resets event times and and temperatures back to the factory presets.
The unit must be re-programmed. The correct time will be retained.
IMPORTANT: always use high quality alkaline batteries
NB. If the display ever goes blank during normal operation, the
batteries will need to be renewed, the unit reset and the time
reprogrammed. The event times and temperatures will be retained.
To change between °C and °F scaling. Press V and - together to
toggle between °C and °F temperature scaling.
2.9 Toggle between °C and °F scaling
Danfoss Heating
11
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
FR
GB
Index
1.0 Informations de base
1.1 Votre thermostat d’ambiance programmable ....................... 12
1.2 Programmes Prédéfi nis ................................................................. 12
1.3 Avant de commencer ..................................................................... 13
1.4 Réglage de l’heure .......................................................................... 13
1.5 Exécution du programme............................................................. 13
2.0 Informations avancées
2.1 Avant de modifi er les programmes prédéfi nis ..................... 14
2.2 Modifi cation des programmes prédéfi nis ..............................14
2.3 Exécution de votre programme ................................................. 15
2.4 Dérogations ....................................................................................... 15
2.5 Modifi cation de l’affi chage pour indiquer l’heure ou la
température ambiante eff ective ............................................... 15
2.6 Pour modifi er temporairement la température
programmée ..................................................................................... 15
2.7 Protection anti-gel et mode thermostat .................................16
2.8 Changer le mode d’affi chage en 12 heures ou
24 heures ............................................................................................16
2.9 changer l’unité de température entre °C et °F ....................... 16
3.0 Remplacement des Piles ..................................................................... 17
4.0 Remise à zéro du thermostat ............................................................ 17
Notice d’utilisation
Série TP4000
Thermostats d’ambiance programmable
TP4000
12
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
FR
1.0 Informations de base
1.1 Votre thermostat d’ambiance programmable
Le TP4000 vous permet de programmer jusquà 6 périodes de
températures auxquelles votre chauff age sallumera et séteindra
chaque jour.
Il comprend plusieurs fonctions supplémentaires pour l’utilisateur
dont protection antigel, mode thermostat et affi chage de l’heure ou
de la température.
1.2 Programmes Prédéfi nis
Votre TP4000 est livré préalablement programmé avec une série
d’heures et de températures de fonctionnement qui conviennent
généralement à la plupart des utilisateurs
.
Si vous souhaitez modifi er l’un de ces réglages, il vous suffi t de suivre
les instructions aux page 14
.
Suivez tout d’abord les points indiqués à la page 13 pour régler
l’heure.
Période Heure Temp °C
1 06:30 20
2 08:30 15
3 11:30 20
4 13:30 15
5 16:30 21
6 22:30 15
Danfoss Heating
13
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
FR
1.3 Avant de commencer
Ouvrez le volet à l’avant du thermostat et
appuyez sur le bouton RESET à l’aide d’un
objet non métallique jusquà ce que l’affi chage
disparaisse. Cette opération permet de
sassurer que les programmes d’usine sont
réglés et que le processeur du thermostat
fonctionne correctement.
1.4 Réglage de l’heure
Remarque: l’horloge s’affi che en mode 24 heures.
Presser en même temps PROG et Λ jusqu’à ce
que l’heure clignote
Utilisez les boutons + ou – pour régler
l’HEURE
(appuyez sur les boutons en les maintenant
enfoncés pour changer l’heure par incréments
de 10 min).
Appuyez sur PROG pour confi rmer l’heure.
1.5 Exécution du programme
Si les programmes prédéfi nis indiqués à la
page 12 vous conviennent, aucune autre
manipulation ne sera nécessaire.
Votre appareil est désormais en mode RUN. (Fonctionnement).
RESET
TP4000
14
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
a) Appuyez sur PROG jusquà ce que les
1
ères
heure et température prédéfi nies
s’a chent à lécran.
b) Utilisez les boutons + ou – pour régler
l’HEURE (appuyez sur les boutons en
les maintenant enfoncés pour changer
l’heure par incréments de 10 min).
c) Utilisez les boutons Λ ou V pour régler la
TEMPERATURE.
d) Appuyez sur PROG pour passer aux heure
& température prédéfi nies suivantes
(Période 2).
e) Répétez les points b, c & d pour la
programmation des Périodes 3, 4, 5 & 6.
FR
Important
Le thermostat doit être programmé en séquence. Les heures de
réglage ne peuvent pas être programmées hors séquence.
Si vous souhaitez laisser une heure prédéfi nie inchangée, il vous
suffi t d’appuyer sur PROG pour passer au réglage suivant.
Au cours de la programmation, si aucune touche nest actionnée
pendant 2 minutes, l’appareil repassera automatiquement en
mode RUN (Fonctionnement), et le programme confi guré à cet
instant
sera activé.
2.0 Informations avancées
2.1 Avant de modifi er les programmes prédéfi nis
2.2 Modifi cation des programmes prédéfi nis
Danfoss Heating
15
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
FR
2.3 Exécution de votre programme
Appuyez sur PROG – les deux points sur l’écran
LCD se mettront à clignoter. Votre chauff age
sera maintenant contrôlé par les heures et
températures programmées.
2.4 Dérogations
Vous pouvez parfois avoir besoin de modifi er temporairement le
mode de fonctionnement de votre chauff age, ex. en raison d’un temps
exceptionnellement froid. Le TP4000 intègre plusieurs fonctions de
dérogation pour l’utilisateur, qui peuvent être sélectionnées sans aff ecter
la programmation du thermostat.
2.5 Modifi cation de l’affi chage pour indiquer
l’heure ou la température ambiante eff ective
• appuyez sur + et – simultanément pour
basculer entre les réglages.
2.6 Pour modifi er temporairement la
température programmée
• Appuyez sur Λ ou V jusquà ce que la
température désirée saffi che.
(La priorité s’annulera automatiquement
au début de la période suivante
programmée).
TP4000
82
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
3.0 Baterijos pakeitimas
Nusekus baterijoms, LCD ekrane atsiras ir
pradės mirksėti baterijos simbolis. Per 15 dienų
jūs turėsite pakeisti bateriją, kol termostatas
neišsijungs.
Keičiant baterijas, nuimkite senas baterijas ir įstatykite naujas per
vieną minutę, kad nepradingtų užprogramuotos funkcijos.
!
SVARBU: visuomet naudokite aukštos kokybės šarmines
baterijas
NB. Jeigu kada nors normalaus darbo metu ekranas taptų tuščias,
baterijas reiktų pakeisti, naujai nustatyti termostatą ir perprogramuoti
laiką. Įvykių laikai ir temperatūros bus išsaugoti.
Perjungimas tarp °C ir °F skalės. Vienu metu spauskite Λ ir + ir
pakeiskite temperatūros skalę iš °C į °F ir atvirkščiai.
2.9 Perjungimas tarp °C ir °F skalės
Norint pakeisti laikrodžio ekrane laiko režimą iš 12 valandų į 24
valandų ir atvirkščiai, spauskite vienu metu Λ ir +.
2.8 Perjungimas tarp 12 valandų ir 24 valandų
laikrodžio režimo
82


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Danfoss TP4000 Range at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Danfoss TP4000 Range in the language / languages: English, Dutch, French, Polish, Turkish, Spanish as an attachment in your email.

The manual is 1,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info