The oilburner operates as follows: The burnermotor controls both airfan and fuel
pump. By means of an electric valve, the fuel is pumped into the burner. Here the
fuel gets vaporized and set to fire by two sparks. To achieve a high efficiency level,
the flames and hot smoke gasses are blown through the tube coil to an optimum.
This causes a minimum of lost heat through the funnel. Ignition is continuously, so
that hardly any smoke occurs at starting the burner.
The fuelpump is protected against running dry by a fuel level meter (fig. 3A;198). If
the machine runs out of fuel, the switch turns of the burnermotor and so the
fuelpump stops functioning. The cleaner now only gives cold water until fuel is
added again.
Remember that the return mains is not cooled when the high pressure cleaner has
run out of fuel, because the fan of the burnermotor does not function. Do not let
the machine run too long when no water is needed.
7.0 POSSIBILITIES OF FAILURE
1 Machine does not function:
* blown fuse - renew fuse.
* thermal failure - turn on the main switch (fig. 1;217). (fails
repeatedly: look under point 2).
2 Thermal relay (main switch) keeps failing:
* blown fuse - renew.
* pressure too high - lower pressure, clean nozzle.
* too low tension current - remove too thin or too long extension
cords.
* defective motor - replace or repair.
3 The burner does not work:
* thermostat not on - switch on (fig. 1;218).
* fueltank empty - refill (fig. 1;191).
* pollution in the fuel system - clean tank, pipes and filters
* sprayer clogged - clean sprayer and strainer.
* water mains switch does - set pressure regulator (fig. 1;173)
not work; not enough water higher. See point 4.
* microswitch does not turn - see point 4.
on owing to too low pressure
* magnetic valve of the fuel - check electric connections.
supply does not open
* no ignition - check ignition transformer, ignition
cords and electrodes. Clean if necessary,
and replace defective parts.
4 Pressure is too low:
* wrong nozzle in spouting gun - mount right nozzle.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dampcomat HWO1000 - 66603 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dampcomat HWO1000 - 66603 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info