500365
19
Zoom out
Zoom in
Previous page
1/44
Next page
17
2.0 PLACING
The HWO 1000 high pressure cleaner is equipped with 4 rubber wheels which
allow the machine to move lightly even on difficult surfaces.
The DAMPCOMAT high pressure cleaner should be placed always as horizontal
as possible. Do not use the cleaner in an enclosed space and in rooms with
danger of explosion. Take care of sufficient waterdischarge and sufficient air for
the burner. Because of the smoke produced by the burner, the machine should
only be used in open air or in very well ventilated rooms. If the machine is to be
connected to a permanent funnel, place a trapezium shaped cap about 10 cm
above the chimney of the cleaner. Funneldiameter should be at least 18 cm.
Protect the machine in winter against temperatures below zero. Place the cleaner
in a frostfree environment or let antifreeze circulate through the machine.
2.1 ELECTRIC CONNECTION
In the factory the machine is already fully equipped with cables. The machine now
has to be connected to your own electric circuit. Connect the cleaner to a separate
group. Beware that voltage and amperage of your electric circuit meet the needs
of the machine. Therefore check technical details (9.0). Use only cables with the
right diameter. The factory advises to use cables of at least 2,5 qmm. Never lay
the plug and contact cover in water, and never put them in a place where it can get
wet from spraying. Danger for electrocution!
2.2 WATERCONNECTION
For quick connection of hoses are cleaner and accessories equipped with high
pressure screw couplings and GEKA waterhose couplings. If your water taps get
also equipped with GEKA couplings, your waterhose will always easily fit.
Beware that the cleaner always gets sufficient water. The waterconsumption of the
machine reaches up to 1000 ltrs/hour. That amount your waterconduit should
deliver. So use hoses of sufficient diameter and turn tap fully open. Beware that
hoses do not bend or leak. Do not place any heavy objects on hoses, nor place
hoses over sharp edges.
3.0 FIRST USE
1. Check if the instructions mentioned above have been executed.
2. Check the oillevel of the highpressure pump (fig. 3;133). Possibly oil has been
lost during transport. Fill if necessary with good quality oil (SAE 85-90) through
the black fillercap. The level has to be between the top of the oilglass and the
red dot on it.
4.0 OPERATING
Fill the fuel tank (fig. 1;191) with diesel oil or domestic fuel oil. The machine is built
for optional detergent usage, from:
internal tank:
this tank (fig. 3;169) and the fillercap are placed under the hood.
separate detergent can:
place the suction hose in the separate detergent can.
Refill detergent tank if necessary. Use exclusively good cleansing agents, in liquid
form to prevent blockages and sludging in hoses, pipes, tubecoil etc. If powder
detergent is needed, mix them thoroughly with (hot) water and then use them in
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dampcomat HWO1000 - 66603 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dampcomat HWO1000 - 66603 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info