730844
7
Zoom out
Zoom in
Previous page
1/16
Next page
4 Operation
Operation manual
7
FTXP20~71L2V1B
R32 split series
3P511999-1C – 2018.01
2 Press to stop.
Result: disappears from the LCD.
Note: Powerful operation can only be set when the unit is running.
Press to cancel this mode; disappears from the LCD.
4.3.6 Econo operation
This is a function which enables efficient operation by limiting the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.
INFORMATION
Powerful and Econo operation CANNOT be used at the
same time. The last selected function takes priority.
Econo operation reduces power consumption of the
outdoor unit by limiting the rotation speed of the
compressor. If power consumption is already low,
Econo operation will NOT further reduce power
consumption.
To start/stop Econo operation
1 Press to start.
Result: is displayed on the LCD.
Note: Econo operation is NOT available in Fan only mode.
2 Press to stop.
Result: disappears from the LCD.
a
A
B
b
c
d
A Running current and power consumption
B Time
a Maximum during normal operation
b Maximum during Econo operation
c Normal operation
d Econo operation
The diagram can be used for illustrative purposes only.
The maximum running current and power consumption of the air
conditioner in Econo operation varies with the connected outdoor
unit.
4.3.7 OFF/ON timer operation
Timer functions are useful for automatically switching the air
conditioner on/off at night or in the morning. You can also use OFF
timer and ON timer in combination.
INFORMATION
Program the timer again in case of:
A breaker has turned the unit off.
A power failure.
After replacing batteries in the user interface.
To start/stop OFF timer operation
Use this feature if the unit is operating and you want to stop
operation after a certain time.
1 Press .
Result: is displayed on the LCD and the timer lamp
lights up.
2 Press again if you want to change the time setting.
INFORMATION
Each time is pressed, the time setting advances by
1 hour. The timer can be set between 1 to 12 hours.
Example: If is set when the unit is operating, operation
will stop after 5hours.
3 To cancel the setting, press .
Result: and the time setting disappear from the LCD and the
timer lamp goes off.
INFORMATION
Night set mode
When the OFF timer is set, the air conditioner
automatically adjusts the temperature setting (0.5°C up in
cooling, 2.0°C down in heating) to prevent excessive
cooling/heating and ensure a comfortable sleeping
temperature.
To start/stop ON timer operation
Use this feature if the unit is NOT operating and you want to start
operation after a certain time.
1 Press .
Result: is displayed on the LCD and the timer lamp
lights up.
2 Press again if you want to change the time setting.
INFORMATION
Each time is pressed, the time setting advances by
1 hour. The timer can be set between 1 to 12 hours.
Example: If is set when the unit is NOT operating,
operation will start after 2hours.
3 To cancel the setting, press .
Result: and the time setting disappear from the LCD and the
timer lamp goes off.
To combine OFF timer and ON timer
1 To set the timers, refer to "To start/stop OFF timer operation"on
page7 and "To start/stop ON timer operation"on page7.
Result: and are displayed on the LCD.
Example:
2 If is set when the unit is operating.
Result: Operation stops in 1 hour and then starts 7 hours
later.
3 If is set when the unit is NOT
operating.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin FTXP50L2V1B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin FTXP50L2V1B in the language / languages: English as an attachment in your email.

The manual is 1,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin FTXP50L2V1B

Daikin FTXP50L2V1B User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.