4 Operation
Operation manual
5
FTXP20~71L2V1B
R32 split series
3P511999-1C – 2018.01
4.2 When to use which feature
You can use the following table to determine which features to use:
Feature Tasks
Basic features
Operation modes and
temperature
To start/stop the system and to set the
temperature:
Heat up or cool down a room.
Blow air in a room without heating or
cooling.
Decrease the humidity in a room.
In Automatic mode, automatically
select an appropriate temperature
and operation mode.
Airflow direction
To adjust the airflow direction (swing or
fixed position).
Airflow rate
To adjust the amount of air blown into
the room.
To run more quietly.
Advanced features
Econo
To use the system when you are also
using other power-consuming
appliances.
To save energy.
Comfort
To provide a comfortable airflow that
does NOT come in direct contact with
people.
Powerful
To cool down or heat up the room
quickly.
ON timer + OFF
timer
To automatically turn ON or OFF the
system.
4.3 Operation mode and temperature
setpoint
When. Adjust the system operation mode, and set the temperature
when you want to:
Heat up or cool down a room
Blow air in a room without heating or cooling
Decrease the humidity in a room
What. The system operates differently depending on the user
selection.
Setting Description
Automatic
The system cools down or heats up a
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.
Drying
The system decreases the humidity in a
room without changing the temperature.
Heating
The system heats up a room to the
temperature setpoint.
Cooling
The system cools down a room to the
temperature setpoint.
Fan
The system only controls the airflow
(airflow rate and airflow direction).
The system does NOT control the
temperature.
Additional info:
Outside temperature. The system's cooling or heating effect
decreases when the outside temperature is too high or too low.
Defrost operation. During heating operation, frost might occur on
the outdoor unit and decrease the heating capacity. In that case,
the system automatically switches to defrosting operation to
remove the frost. During defrosting operation, hot air is NOT
blown from the indoor unit.
4.3.1 To start/stop operation and to set the
temperature
: Operation mode = Automatic
: Operation mode = Drying
: Operation mode = Heating
: Operation mode = Cooling
: Operation mode = Fan only
: Shows the set temperature.
1 Start operation by pressing one of the following buttons.
Result: The operation lamp lights up.
Mode Press Result
Automatic operation
Cooling operation
Drying operation
Heating operation
Fan only operation
2 Press or on the button one or more times to set the
temperature.
Note: When using drying or fan only operation mode, you CANNOT
adjust the temperature.
Cooling
operation
Heating
operation
Automatic
operation
Drying or fan
only operation
18~32°C 10~30°C 18~30°C
3 Press to stop operation.
Result: The operation lamp goes off.
4.3.2 Airflow rate
Note: If the unit reach the temperature set point in cooling, heating
or automatic mode. Fan will stop operating.
1 Press to choose:
5 airflow rate levels, from " " to " "
Automatic operation
Indoor unit quiet operation. When the airflow is set to
" ", the noise from the unit will be reduced.
Note: When using drying operation mode, you CANNOT adjust the
airflow rate setting.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin FTXP50L2V1B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin FTXP50L2V1B in the language / languages: English as an attachment in your email.

The manual is 1,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin FTXP50L2V1B

Daikin FTXP50L2V1B User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info