4 Operation
User reference guide
6
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
You can… Location
Check which space operation mode is
currently used.
Home pages:
Room temperature
Leaving water
temperature (main
+ additional)
Set the space operation mode. Menu structure
Restrict when automatic changeover is
possible.
To determine if a heating/cooling heat pump
model is installed
1 Press to go to the menu structure.
2 Check if [4] Operation mode is listed. If so, a heating/cooling
heat pump model is installed.
To check which space operation mode is currently
used
1 Go to one of the following the home pages:
Room temperature home page (Room)
Main leaving water temperature home page (LWT main)
Additional leaving water temperature home page (LWT add)
2 Check the status icon:
If you see… Then…
Operation mode = heating.
Unit is NOT heating up your space.
However, the DHW tank can be
heating up.
Operation mode = heating.
Unit is heating up your space at this
moment.
Operation mode = cooling.
Unit is NOT cooling down your space.
However, the DHW tank can be
heating up.
Operation mode = cooling.
Unit is cooling down your space at this
moment.
To set the space operation mode
1 Go to [4]: > Operation mode.
2 Select one of the following and press
:
If you select… Then the space operation mode is…
Heating Always heating mode.
Cooling Always cooling mode.
Automatic Automatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
takes monthly restrictions into account.
Note: Automatic changeover is only
possible under certain conditions.
To restrict when automatic changeover is possible
1 Go to [7.5]: > User settings > Allowed operation mode.
2 Select a month and press
.
3 Select Heating only, Cooling only or Heating/Cooling, and press
.
Typical automatic changeover restrictions
When Restriction
During cold season.
Example: October, November, December,
January, February and March.
Heating only
During warm season.
Example: June, July and August.
Cooling only
In-between.
Example: April, May and September.
Heating/Cooling
4.4.3 Controlling the temperature
About controlling the temperature
Depending on the system layout and installer configuration, you use
a different temperature control:
Room thermostat control (linked or NOT linked)
Leaving water temperature control
External room thermostat control
To determine which temperature control you are using
(method 1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are using
(method 2)
If you have 2 user interfaces, perform the following procedure on the
user interface at the indoor unit.
1 Press
multiple times to switch between home pages, and
check if the additional leaving water temperature home page
(LWT add) is available:
If … Then you have…
Available A main zone and an additional
zone
NOT available Only a main zone
Typical additional leaving water temperature home page:
User profile = Basic User profile = Detailed
45°C
1 5 : 2 0
D e s i r e d t e m p e r a t u r e
Mon
LWT add
45°C
1 5 : 2 0
2 2 : 0 0
D e s i r e d t e m p e r a t u r e
Mon
LWT add
Mon
2 Go to [6]: > Information.
3 Press for more than 5 seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu
title.
4 Check the following:
If… Then the temperature control is…
Main zone Additional zone
(if any)
Room temperature is
listed under:
[6.1]: > Information
> Sensor information
Room thermostat
control.
Go to next step to
check if leaving
water set point and
room temperature
set point are
linked.
External room
thermostat control.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin Altherma at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin Altherma in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin Altherma

Daikin Altherma User Manual - German - 28 pages

Daikin Altherma User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info