554159
22
Zoom out
Zoom in
Previous page
1/24
Next page
4 Operation
User reference guide
5
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
Icon Description
Emergency operation is active.
4.3 Basic usage
4.3.1 Using home pages
About home pages
You can use the home pages to read out and change settings that
are meant for daily usage. What you can see and do on the home
pages is described where applicable. Depending on your system
layout, the following home pages may be possible:
Room temperature (Room )
Main leaving water temperature (LWT main)
Additional leaving water temperature (LWT add)
DHW tank temperature (Tank)
To go to a home page
1 Press .
Result: One of the home pages is displayed.
2 Press
again to display the next home page (if any).
4.3.2 Using the menu structure
About the menu structure
You can use the menu structure to read out and configure settings
that are NOT meant for daily usage. What you can see and do in the
menu structure is described where applicable. For an overview of
the menu structure, see "4.8 Menu structure: Overview" on
page 19.
To go to the menu structure
1 From a home page, press .
Result: The menu structure is displayed.
>
>
>
>
>
>
1
OK
H o l i d a y
S e t t i m e / d a t e
Q u i e t m o d e
O p e r a t i o n m o d e
A u t o
H e a t i n g
S e l e c t s c h e d u l e s
I n f o r m a t i o n
S e l e c t S c r o l l
To navigate in the menu structure
Use , , , , and .
4.3.3 Turning ON/OFF controls
About turning ON/OFF controls
Before you can control… You have to turn ON…
Room temperature Room temperature control.
Main (+ additional) leaving water
temperature
Main (+ additional) leaving water
temperature control.
Main and additional leaving water
temperature control are always
turned ON or OFF together.
DHW tank temperature Domestic hot water control.
If you turn ON… Then…
Room temperature control Main (+ additional) leaving water
temperature control is
automatically turned ON.
If you turn ON… Then…
Main (+ additional) leaving water
temperature control
Room temperature control is
NOT automatically turned ON.
If you turn OFF… Then…
Room temperature control Main (+ additional) leaving water
temperature control is NOT
automatically turned OFF.
Main (+ additional) leaving water
temperature control
Room temperature control is
automatically turned OFF.
To check if a control is turned ON or OFF
1 Go to the home page of the control.
Example: Room temperature home page (Room ).
2 Check if the LED is ON or OFF.
Note: If the control is turned OFF, OFF is also displayed on the
screen.
To turn ON or OFF the room temperature control
1 Go to the room temperature home page (Room).
2 Press .
To turn ON or OFF the leaving water temperature
(main + additional) control
1 Go to one of the following the home pages:
Main leaving water temperature home page (LWT main)
Additional leaving water temperature home page (LWT add)
2 Press .
To turn ON or OFF the domestic hot water control
1 Go to the DHW tank temperature home page (Tank).
2 Press .
4.4 Space heating/cooling control
4.4.1 About space heating/cooling control
Controlling space heating/cooling typically consists of the following
stages:
1 Setting the space operation mode
2 Controlling the temperature
4.4.2 Setting the space operation mode
About space operation modes
Depending on your heat pump model, you have to tell the system
which space operation mode to use: heating or cooling.
If a… heat pump model
is installed
Then…
Heating/cooling The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.
Heating only The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.
To tell the system which space operation to use, you can do the
following:
4 Operation
User reference guide
14
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
To configure the holiday (when you go away)
1 Go to [2]: > January.
2 Select Away.
3 Configure the holiday mode settings (when you go away).
Possible holiday mode settings (when you go
away)
Setting Description
From and Until First and last day of your holiday.
Operation mode
Operation mode used during your holiday.
Heating Set point used during your holiday when the unit
is operating in heating mode.
Cooling Set point used during your holiday when the unit
is operating in cooling mode.
To activate or deactivate the holiday mode
Prerequisite: You have configured the holiday.
1 Go to [2.1]: > Holiday > Holiday.
2 Do one of the following:
To activate, select Yes and press .
To deactivate, select No and press .
Usage example: You go away during the winter
If you are in the following situation:
In 2 days, you go away for 2 weeks during the winter.
You want to save energy, but prevent your house from freezing.
Then you can do the following:
1 Configure the holiday.
Go to [2]:
> Holiday, and configure the following settings:
Setting Value
Holiday mode Away
From 2 February 2013
Until 16 February 2013
Operation mode Heating
Heating 12°C
2 Activate the holiday mode.
Go to [2.1]: > Holiday > Holiday.
Select Yes and press .
Advantage:
Before and after your holiday, your normal schedule will be used.
During your holiday, you save energy and prevent your house
from freezing.
Usage example: You come home during your
holiday
If you are in the following situation:
You configured and activated the holiday mode (Away).
During your holiday, you come home for a few hours and want to
use your normal schedule.
Then you can do the following:
1 Deactivate the holiday mode.
2 When you go away again, activate the holiday mode again.
Advantage:
You do NOT have to change your schedule or holiday configuration
(= easy).
4.6.3 Reading out information
About reading out information
The amount of information you can read out in the menu structure
([6]: Information) depends on your user permission level:
End user (= default)
Adv. end user: You can read out more information.
To switch between user permission levels
(End user and Advanced end user)
1 Go to [6] or any of its submenus: > Information.
2 Press for more than 4 seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu
title.
3 If you do NOT press any button for more than 1 hour or press
again for more than 4 seconds, the user permission level
switches back to End user.
To read out information
Go to [6]: > Information.
Possible read-out information
If user permission level = End user, you can read out the following
information:
In menu… You can read out…
[6.1] Sensor information Room, tank and outside
temperature.
[6.2] Energy metering Energy consumption and
produced energy (only totals).
[6.3] Error handling Error history and contact/
helpdesk number.
[6.4] User permission level Current user permission level.
If user permission level = Adv. end user, you can read out the
following additional information:
In menu… You can read out…
[6.2] Energy metering Energy consumption and
produced energy (detailed
information).
[6.5] Actuators Status/mode of each actuator.
Example: Domestic hot water
pump ON/OFF.
[6.6] Operation modes Current operation mode.
Example: Defrost/oil return
mode.
[6.7] Running hours Running hours of the system.
[6.8] Version Version information about the
system.
4.6.4 Configuring date, time, units of
measurement, contrast and backlight
To configure time and date
Go to [1]: > Set time/date.
To configure units of measurement
Go to [7.6]: > User settings > Unit of measurement.
4 Operation
User reference guide
15
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
Possible units of measurement settings
Setting Possible units of measurement
Decimal point Dot
Comma
Temperature °C
°F
Produced energy kWh
MBtu
Flow l/min
GPM
To configure the contrast of the user interface
Go to [7.1.1]: > User settings > Display > Contrast.
To configure the backlit LCD time of the user
interface
Go to [7.1.2]: > User settings > Display > Backlit LCD time.
4.6.5 Configuring user profile and home pages
To set a user profile
1 Go to [7.1.3]: > User settings > Display > User profile.
2 Select a user profile and press
.
Possible user profiles
If user profile = Detailed, you can see and do more on the home
pages.
User profile Example
Basic
20.0°C
1 5 : 2 0
A c t u a l t e m p e r a t u r e
Mon
Room
Detailed
20.C
1 5 : 2 0
1 7 : 3 0
A c t u a l t e m p e r a t u r e
S c h e d u l e d
Tue
Mon
Room
To configure which home pages are made
available to the end user
1 Go to [7.1.4]: > User settings > Display > Available home
pages.
Result: The home pages that are possible for your system
layout are listed.
2 Select a home page and press
.
3 Do one of the following:
To display the home page, select Yes and press .
To hide the home page, select No and press .
4.6.6 Locking and unlocking buttons and
functions
About locking and unlocking
You can use the following locking modes:
Child lock: Locks all buttons to prevent children from changing
settings.
Function lock: Locks a specific function to prevent people from
changing its settings.
Possible function locks
Lock If active, people cannot…
Room On/OFF Turn ON or OFF the room
temperature control.
LWT On/OFF Turn ON or OFF the leaving
water temperature (main +
additional) control.
Tank On/OFF Turn ON or OFF the domestic
hot water control.
Temperature up/down Adjust temperatures.
Quiet mode Use quiet mode.
Holiday Use holiday mode.
Operation mode Set the space operation mode.
User settings
Change settings in [7]: > User
settings.
To check if locking is active
1 Press to go to one of the home pages.
2 If
is displayed, child lock is active.
Note: If you are on a home page and try to use a function that is
locked, is displayed for 1 second.
To activate or deactivate child lock
1 Press to go to one of the home pages.
2 Press
for more than 5 seconds.
To activate or deactivate a function lock
1 Press to go to the menu structure.
2 Press
for more than 5 seconds.
3 Select a function and press .
4 Select Lock or Unlock, and press
.
4.7 Preset values and schedules
4.7.1 Using preset values
About preset values
You can define preset values for multiple controls. Preset values
make it easy to use the same value in many places (schedules and
room temperature home page ( and )). If you later want to change
the value, you only have to do it in one place.
To define preset values
1 Go to [7.4]: > User settings > Preset values.
2 Select for which control you want to define a preset value.
Example: Room temperature.
3 Select a preset value and press
.
Example: Comfort (heating).
4 Select a temperature and press .
Possible preset values
Control Preset value Where used
Room
temperature
Comfort Room temperature
schedules
4 Operation
User reference guide
17
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
7 Save the schedule and give it a name.
To program the schedule for Monday
1 Use and to select Monday.
2 Press to enter the schedule for Monday.
3 Program the schedule for Monday:
Use and to select an entry.
Use and to change the value of an entry.
To copy from one day to another
1 Select the day from which you want to copy and press .
Example: Monday.
2 Select Copy day and press .
3 Set the days you want to copy to Yes and press .
Example: Tuesday = Yes, Wednesday = Yes, Thursday = Yes
and Friday = Yes.
To save the schedule
1 Press , select Save schedule and press .
2 Select User defined 1, User defined 2 or User defined 3 and
press .
3 Change the name and press .
Example: MyWeekSchedule
4.7.4 Predefined schedules: Room temperature
+ leaving water temperature (main)
: Desired temperature = Preset value (Comfort)
: Desired temperature = Preset value (Eco)
Predefined 1 (heating)
Mon - Fri
07:00 09:00 17:00 23:00
Sat - Sun
23:0008:00
Predefined 2 (heating)
Mon - Fri
07:00 09:00 17:0012:00 23:0014:00
Sat - Sun
23:0008:00
Predefined 3 (heating)
Mon - Sun
23:0008:00
Predefined 1 (cooling)
Mon - Fri
17:00 20:00
Sat - Sun
12:00 20:00
Predefined 2 (cooling)
Mon - Fri
17:0012:00 14:00 20:00
Sat - Sun
12:00 20:00
Predefined 3 (cooling)
Mon - Sun
12:00 20:00
4.7.5 Predefined schedules: Leaving water
temperature (additional)
: Additional zone = On
: Additional zone = OFF
Predefined 1 (heating)
Mon - Fri
07:00 09:00 17:00 23:00
Sat - Sun
08:00 23:00
Predefined 2 (heating)
Mon - Fri
07:00 09:00 17:0012:00 23:0014:00
Sat - Sun
08:00 23:00
Predefined 3 (heating)
Mon - Sun
08:00 23:00
Predefined 1 (cooling)
Mon - Fri
17:0017:00 20:00
Sat - Sun
20:0012:00
Predefined 2 (cooling)
Mon - Fri
17:0012:00 14:00 20:00
Sat - Sun
20:0012:00
Predefined 3 (cooling)
Mon - Sun
20:0012:00
4 Operation
User reference guide
18
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
4.7.6 Predefined schedules: DHW tank
temperature
a
: Start production of domestic hot water. Desired DHW tank
temperature = Preset value (Storage comfort)
b
: Start production of domestic hot water. Desired DHW tank
temperature = Preset value (Storage eco)
Predefined 1
Mon - Sun
a
b
:00
Predefined 2
Mon - Sun
a
b
:00 :00
Predefined 3
Mon - Fri
a
b
:00
Sat - Sun
a
b
:00 :00
4 Operation
User reference guide
19
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
4.8 Menu structure: Overview
< >
Date
Time
Daylight Saving Time
Clock type
Set time/date[1]
Holiday
Holiday mode
From
Until
Holiday[2]
Use day schedule
Home
Room temperature
LWT main
LWT additional
Tank temperature
Select schedules[5]
Sensor information
Energy metering
Error handling
User permission level
Information[6]
Actuators
Operation modes
Running hours
Version
Display
Temperature lock
Set schedules
Preset values
User settings
[7]
Allowed operation mode
Unit of measurement
Holiday
Holiday mode
From
Until
Holiday[2]
Operation mode
Away
Heating
Cooling
Consumed electr.
Produced energy
Energy metering[6.2]
Error history
Contact/helpdesk number
Error information[6.3]
User interface
Indoor unit
Outdoor unit
Version[6.8]
Contrast
Backlit LCD time
User profile
Available home pages
Display[7.1]
Room temperature
LWT main
Tank temperature
Quiet level
Preset values
[7.4]
Room temp.
LWT main
LWT additional
Tank temp.
Set schedules
[7.3]
Booster heater permission
Quiet mode
DHW pump
[3]
Operation mode[4]
Quiet mode
10 Glossary
User reference guide
22
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
10 Glossary
DHW = Domestic hot water
Hot water used, in any type of building, for domestic
purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the heat pump.
Dealer
Sales distributor for the product.
Authorized installer
Technical skilled person who is qualified to install the
product.
User
Person who is owner of the product and/or operates the
product.
Applicable legislation
All international, European, national and local directives,
laws, regulations and/or codes that are relevant and
applicable for a certain product or domain.
Service company
Qualified company which can perform or coordinate the
required service to the product.
Installation manual
Instruction manual specified for a certain product or
application, explaining how to install, configure and maintain
it.
Operation manual
Instruction manual specified for a certain product or
application, explaining how to operate it.
Accessories
Labels, manuals, information sheets and equipment that are
delivered with the product and that need to be installed
according to the instructions in the accompanying
documentation.
Optional equipment
Equipment made or approved by Daikin that can be
combined with the product according to the instructions in
the accompanying documentation.
Field supply
Equipment not made by Daikin that can be combined with
the product according to the instructions in the
accompanying documentation.
4P313778-1B 2012.11
Copyright 2012 Daikin
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin Altherma at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin Altherma in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin Altherma

Daikin Altherma User Manual - German - 28 pages

Daikin Altherma User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info