4  •  EN
Absorption (Lamp 3)
Complete charge up to virtually 100%. The terminal voltage is maintained at the set level. During this phase the current 
tapers successively. Once the current has tapered to the set limit, this phase switches to being timed. If the total time for 
Absorption exceeds the time limit the charger automatically switches to maintenance. 
Analysis (Lamp 3)
Testing self-discharge. If self-discharge is too high, charging is discontinued and fault mode is indicated. 
Maintenance charging - Float (Lamp 4)
Charging at constant voltage.
Maintenance charging - Pulse (Lamp 4)
State of charge varies between 95% and 100%. The battery receives a pulse when the voltage drops and keeps the 
battery in perfect condition when it is not in use. The charger can be connected for months at a time. The charger 
continuously measures the terminal voltage to determine whether a charging pulse should be initiated. If the battery is 
loaded and/or the battery’s terminal voltage drops the charger starts a charging pulse until the terminal voltage reaches 
the set level. The charging pulse is then discontinued and the cycle is repeated innitely. If the terminal voltage drops 
below a lower limit, the charger automatically goes back to the beginning of the charging curve.
Recond (Lamp 5)
This mode is used to recover deeply discharged ooded batteries. Recondition of deep discharged batteries. The voltage 
increases with reduced current for a limited time period. The higher voltage starts some gassing and mixing of the acid, 
which is benecial for both battery capacity and expected life. Note that the battery could emit explosive gas during 
Recond. Recond is performed between Analysis and Maintenance.
INDICATORS
MODE
SUPPLYNORMAL RECOND
RECOND
SUPPLY
Lamp Description
0 Fault mode, the charging is discontinued. For fault causes, see below.
1 Start mode
2 Bulk charging
3 Absorption charging
4 Maintenance charging
5 Supply
6 Recond reconditioning of completely discharged batteries. 
A Mains voltage connected
B Normal
C Supply
D Recond
Fault mode
The charger goes to fault mode in the following situations:
•  The battery is connected with poles reversed to the charger's terminals.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ctek MXT 14000 AE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ctek MXT 14000 AE in the language / languages: English as an attachment in your email.

The manual is 0,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ctek MXT 14000 AE

Ctek MXT 14000 AE User Manual - German - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info