b The compliance levels in the ISM frequency bands between 150 kHz
and 80 MHz and in the frequency range 80 MHz to 2,7 GHz are intended
to decrease the likelihood that mobile/portable communications
equipment could cause interference if it is inadvertently brought into
patient areas. For this reason, an additional factor of 10/3 has been
incorporated into the formulae used in calculating the recommended
separation distance for transmitters in these frequency ranges.
Recommended separation distances between portable and mobile RF
communications equipment and the BPM220 Series Electronic
Blood Pressure Monitor
Model
c Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio,
AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which
the Model BPM220 Series Electronic Blood Pressure Monitor is used
exceeds the applicable RF compliance level above, the Model BPM220
Series Electronic Blood Pressure Monitor should be observed to verify normal
operation. If abnormal performance is observed, additional measures may
be necessary, such as re-orienting or relocating the Model BPM220 Series
Electronic Blood Pressure Monitor.
d Over the frequency range 150 kHz to 80 MHz, field strengths should be
less than 3 V/m.
0.01 0.12 0.12
0.1 0.38 0.38
1 1.2 1.2
10 3.8 3.8
100 12 12
The BPM220 Series Electronic Blood Pressure Monitor is intended for
use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the Model BPM220 Series
Electronic Blood Pressure Monitor can help prevent electromagnetic
interference by maintaining a minimum distance between portable and
mobile RF communications equipment (transmitters) and the Model BPM220
Series Electronic Blood Pressure Monitor as recommended below, according
to the maximum output power of the communications equipment.
Model
0.23
0.73
2.3
7.3
23
16 17
Rated maximum
output of
transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz 80 MHz to 800 MHz
800 MHz to 2.7 GHz
P
V
d ]
5.3
[
1
=
P
E
d ]
5.3
[
1
=
P
E
d ]
7
[
1
=
For transmitters rated at a maximum output power not listed above the
recommended separation distance d in metres (m) can be estimated
using the equation applicable to the frequency of the transmitter, where
P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher
frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures,
objects and people.
Regarding EMC Statement
a) a statement to the effect that this equipment needs to be installed and put
into service in accordance with the information provided in the ACCOMPANYING
DOCUMENTS; and
b) a statement to the effect that wireless communications equipment such as
wireless home network devices, mobile phones, cordless telephones and their
base stations, walkie talkies can affect this equipment and should be kept at
least a distanced away from the equipment. The distanced is calculated by
the MANUFACTURER from the 800 MHZ to 2,5 GHz column of Table 5 or Table 6
of IEC 60601-1-2:2007, as appropriate.
The crossed out “wheeled bin” icon on the product reminds you of
your obligation that when you dispose of the appliance, it should be
separately collected. Contact your local authority for information
concerning the correct disposal of your old appliance.
Printing errors and modifications provided
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cresta BPM220 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cresta BPM220 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info