618062
18
Zoom out
Zoom in
Previous page
1/42
Next page
175
the following order, the dive parameters relating to:
PO2 Mix 1 -> FO2 Mix 1 -> PO2 Mix 2 -> FO2 Mix 2
-> Safety Factor -> Max Depth -> OFF/ON
where PO2 Mix 1 is the oxygen’s partial pressure of the primary
mixture (MIX1), which the diver may set, as already shown, on
values between 1.0 bar and 1.6 bar, by variations of 0.1 bar. The
same may be done for the second mixture’s (Mix 2) PO2. By
depressing button A ( ) the chosen setting is confirmed.
To return to the normal display depress button B (Mode) for
several seconds (picture 1).
WARNING: The computer keeps the PO2 setting on, until
the diver manually resets it to different values.
Related topics:
2.3.1. - Dive parameters setting
3.3.3. - Mixture changing by diving.
3.3.4. - CNS toxicity display.
3.3.5. - PO2 alarm
3.3.2. - Nitrox mixture(s) oxygen fraction FO2 setting.
WARNING: Check the FO2 value set on the computer prior
to diving!
In order to set the correct oxygen percentage contained in the
Nitrox mixture(s), depress the central button B (Mode) to the
(DIVE) menu, as shown in picture 3, where the parameters may be
modified according to the following scheme: by depressing button
A ( ) it is possible to select the dive parameters relating to:
PO2 Mix 1 -> FO2 Mix 1 -> PO2 Mix 2 -> FO2 Mix 2
-> Safety Factor -> Max Depth -> OFF/ON
where FO2 Mix 1 is the oxygen percentage of Nitrox primary
mixture (MIX1), which can be set on values between 21% and
50%, by O2 variations of 1%. The second mixture’s FO2 (FO2
Mix2) can be set to values between 21% and 99%, by O2 varia-
tions of 1%. This is done by depressing and keeping button C
( ) depressed.
NOTE: By keeping button C ( ) depressed, the computer
automatically stops on the value of the first of the two standard
Nitrox mixtures (EAN 32), corresponding to 32% oxygen.
NOTE: By varying the oxygen mixture percentage, the
computer will display the maximum depth (MAX) that may
be reached with that mixture.
This depth varies according to the set PO2.
Depress button C ( ) to manually set percentages of other
mixtures different from the standard ones.
Depress button A ( ) in order to confirm the desired percen-
tage, which will appear on the display.
Depress button B (Mode) for several seconds to return to
the normal display (picture 1).
NOTE: It is possible to modify the Nitrox mixture(s) setting
even during the surface interval (
with de-saturation in pro-
gress
) (Picture 12a).
This feature is important, especially for divers who carry out a
series of subsequent dives; it allows the modification of one
mixture after having carried out a first air dive without having
to wait until full de-saturation.
i
i
ENGLISH
Manuale ARCHIMEDE II 2008:Manuale 6 26-06-2008 8:26 Pagina 175
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cressi Archimede II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cressi Archimede II in the language / languages: English as an attachment in your email.

The manual is 4,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info