47Operating the control software
24V External Supply: Actual voltage of the external 24 V supply.
10V External Supply: Actual voltage of the external 10 V supply.
RO Tab
The "RO Tab" appears only, if the Condair RS is connected to a Condair RO-A reverse osmosis system
and if the reverse osmosis system was activated in the factory menu.
PS1: Actual inlet pressure of the pump of the reverse osmosis system in
bar.
PS2: Actual pressure in the pressure tank of the reverse osmosis system
in bar.
Guard: Actual status of the pump motor guard switch of the reverse os-
mosis system ("Off"= switch open, "On"= switch closed).
PS3: Actual pressure at the membrane inlet of the reverse osmosis system
in bar.
Regeneration: Actual status of the regeneration switch of the optional
water softener of the reverse osmosis system ("Off"= No regeneration in
progress, "On"= Regeneration in progress).
Leakage: Actual status of the optional leakage monitoring switch of the
reverse osmosis system ("Off"= No leakage present, "On"= Leakage
detected).
47


Need help? Post your question in this forum.

Forumrules
1

Forum

condair-rs

Reset search

  • why drain hose led to left, is it due to electrical on right side.
    Submitted on 29-8-2022 at 23:32

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair RS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair RS in the language / languages: English as an attachment in your email.

The manual is 5,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair RS

Condair RS Installation Guide - English - 80 pages

Condair RS User Manual - Dutch - 80 pages

Condair RS Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info