The following settings appear only, if "Water Mode" is set to "Calculated".
Important: the water quality and the water hardness of the supply water
must be known. Using wrong values for these two parameters may lead to
increased maintenance work and operating malfunctions.
Water Quality: with this setting you determine the water quality of the
supply water.
Factory setting: Untreat. tap water
Options: Untreat. tap water (untreated water from tap water
network)
RO water low (RO water with low conductivity
<5 µS/cm)
RO water high (RO water with high conductivity
>5 µS/cm)
Water Hardness: with this setting you determine the water hardness of
the supply water in °dH (german hardness degree).
Factory setting: 20.0 °dH
Setting range: 1.0 ... 30.0 °dH
Maintenance Extended: with this setting you determine the interval
time in hours for the extended maintenance.
Factory setting: dependent on the steam capacity
Setting range: 100 ... 6'000 h
Standard settings dependent on the water quality
Steam
capacity
Water reduction time Maintenance interval time
Small Maintenance Extended Maintenance
Tap water * RO water ** DI water *** Tap water * RO water **
DI water ***
Tap water * RO water **
DI water ***
5 kg/h 30 min 180 min 360 min 500 h 3000 h 1500 h 3000 h
8 kg/h 20 min 180 min 360 min 500 h 3000 h 1500 h 3000 h
10 kg/h 20 min 180 min 360 min 500 h 3000 h 1500 h 3000 h
16 kg/h 10 min 180 min 360 min 450 h 3000 h 1350 h 3000 h
20 kg/h 7 min 180 min 360 min 400 h 3000 h 1200 h 3000 h
24 kg/h 7 min 180 min 360 min 400 h 3000 h 1200 h 3000 h
30 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
40 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
50 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
60 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
80 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
100 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
120 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
140 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
160 kg/h 5 min 180 min 360 min 350 h 3000 h 1050 h 3000 h
* The default settings for untreated tap water refer to a water hardness of 20 °dH or 36 °fH or 360 ppm, respectively
** Default settings for water from a reverse osmosis system (RO water) >5 ... ≤ 30 μS/cm
*** Default settings for de-ionized water (DI water) ≤ 5 μS/cm
26


Need help? Post your question in this forum.

Forumrules
1

Forum

condair-rs

Reset search

  • why drain hose led to left, is it due to electrical on right side.
    Submitted on 29-8-2022 at 23:32

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair RS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair RS in the language / languages: English as an attachment in your email.

The manual is 5,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair RS

Condair RS Installation Guide - English - 80 pages

Condair RS User Manual - Dutch - 80 pages

Condair RS Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info