61Mounting and installation work
Legend
A1 Continuous humidity controller (active) or humidity sensor
A2 Ohmic humidity ontroller (passive), set jumper JP1 to 10V
A3 On/Off humidity controller, set jumper JP1 to 24V
A4 Limiter signal
B1 Ventilation interlock
B2 Airow monitor
B3 Safety humidistat
B4 External enable contact
F1 Internal fuse driver board 24V supply (1 A, slow acting)
F3 Internal fuse driver board 230V supply (4 A, slow acting)
F5 External fuse heating voltage supply (see table in chapter 5.7.7)
F6 External fuse control voltage (max. 10 A, slow acting)
H1 Remote operating and fault indication (option)
H2 Accessory board (option) for the control of an external fan of the AHU as well as the
optional external valve for the water supply line ushing
J1 Jumper wire, if blower pack safety loop is not connected
J3 Jumper wire, if no monitoring devices are connected to SC1 and SC2
J4 Jumper for activating the termination resistor for Modbus or BACnet MSTP network
(Jumper must be connected, if the Condair EL is the rst or the last unit in the network)
J7 Jumper for activating Modbus or BACnet MSTP communication via RS485 interface (J6).
If jumper is not in place no communication will take place through the RS485 interface.
J8
Termination Linkup system (Jumper must be connected, if the Condair EL is the rst or
the last unit in the Linkup system)
K1 Mains contactor (heating voltage) unit A/unit B
K2 External safety circuit (230V/5A)
Q5 External electrical isolator heating voltage supply
Q6 External electrical isolator control voltage supply
SW1 Rotary switch module identication (Module A: 0, Module B: 1)
X0 Terminal Heating voltage supply (option)
1 Supply cable Module A to Module B - 1,65 m (supplied)
2 Data cable Module A to Module B - 1,65 m (supplied)
3 Linkup cable - 2,5 m (supplied)
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair EL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair EL in the language / languages: English as an attachment in your email.

The manual is 4,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair EL

Condair EL User Manual - English - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info