48
A
B
E
Kitchen
Liquid gas operation
• Regulator “B” is pres-
sed down and kept in
this position for 10
seconds. This is
clearing the pipes
from any oxygen and
gas, which may reach
the burner unit.This,
on a new unit can take
a few attempts.
• The burner is ignited
by pressing button “E”
down a few times.
• To check if the burner is running
put your hand over the chimney
at the right top corner of the
fridge. The regulator is pressed
down some 20-25 seconds longer
to activate the automatic ignition
safety devise, which then controls
the gas supply.
• When the desired temperature is
reached regulator “B” is turned
backwards towards position “MIN”.
• Remember to cut the gas supply
when the refrigerator is no longer
running on gas.
Frigde
Before using your fridge study the
following.
• Cleaning of the fridge.
Before using the fridge you
should clean the inside and out
side with lukewarm water contai-
ning a mild detergent. From time
to time, the PVC-seal of the lid
should be rubbed with a little tal
cum powder.
• The fridge can be used with 12v,
220/240v or gas (Propane or
Butane only).The regulator sup
plied is to fit the blue Camping
Gaz bottle.
Electric operation
If you wish the unit to operate
from 12volts, it is recommended to
save energy it is advisable to pre-
cool with mains 12 hours before
going on tour. Mains are connected
by using the two pin plug fitted on
the back of the fridge unit.
When running on electric power the thermostatic regulator “A” is used.
The regulator is turned all the way to “7” until the desired tempera-
ture is reached, where after, it is turned down the scale until the
temperature is stable.