669018
55
Zoom out
Zoom in
Previous page
1/175
Next page
T-POWER30_T-POWER 30S
55
4.3.2 Startup stage
To light the stove, press the button ‘P4’ for 3 seconds: the message ‘START’ will appear on the display.
The stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.
The stove carries out the startup stages in sequence according to the procedures defined by the parameters that
manage levels and times, reaching the work condition unless anomalies or alarms occur, according to the following
table:
After a certain time has elapsed, if the fume temperature has not reached the minimum permissible value the stove
goes in alarm status.
- Do not use flammable liquids to light the stove.
- In case of persistent failed lighting, contact the Service Centre.
As an alternative it is possible to switch-on the stove if you press the buttons P4 and P5 at the same time for 3
seconds. è possibile accendere la stufa premendo contemporaneamente il pulsante P4 e P5 per 3 secondi. On the
display it will appear “Waiting for request”. In this way the stove is in stand-by and it starts again only when it
recognises a demand for warming the ambient or the sanitary water (if available).
4.4 Work stage
After the 'STARTUP' stage, the stove goes to the 'WORK' mode which represents the normal operation mode.
The user can adjust the heat output from the max. value of 5 to a min. of 1 with the buttons ‘P5’ and ‘P6’.
Clock
Dialogue box
Water temperature
Room temperature
Button ‘P4’
Status
Duration
Devices
Conditions for going to next status
Igniter
Fume
exhaust
Auger Exch.
After time Pr40
After time Pr41
After time Pr41
Fume temperature > Pr13
After
after time Pr02
Room temperature < SET temperature
Fume temperature < Pr14
Room temperature < SET temperature
Water temperature < water SETTING
Fume temperature < Pr14
Every Pr03
ON/OFF to switch off
(*) Pr39 Starts from when fume T.< Pr13
OFF
START – CLEANING
PELLET PREFILL
WAITING FLAME
PELLET LOAD
WORK
MODULATES WORK
BRAZIER CLEANING
WORK
FINAL CLEANING
FIRE PRESENT
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola TERMO POWER 30S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola TERMO POWER 30S in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info