669031
10
Zoom out
Zoom in
Previous page
1/17
Next page
9
Termo Diana ceramic
The heating stove must never be used without being connected to the heating system and respective
circuit with open expansion tank.
The sides and back must be at least 20 cm from flammable materials. If the floor is made of flammable material
(wood, carpets, etc.) provide for a protection base in sheet metal (recommended min. thickness 2-3 mm).
2.5 Connection to the flue
The TERMO DIANA heating stove must be connected to the flue by means of the collar on the hotplate, using
flue pipes that are readily available on the market. Connection to the chimney must be made using sturdy,
stable pipes, with a recommended minimum wall thickness of 1.5-2 mm. The flue pipe must possibly be straight,
to avoid pressure losses, and towards the flue. The ends of the flue pipe must be tight.
To ensure regular operation, the flue draught with stove operating must be between 10 and 14 Pa.
For optimum stove efficiency, a draught control or
damper must be fitted in the
flue pipe or chimney.
Every unit must eliminate the fumes through its own flue; never use the same flue for several units.
2.6 Termo Diana plumbing diagram
2.7 Air flow in room
M - delivery F 1”
R - return F 1”
P - hole for probe pocket F ½ “
S
-
drain F ½ “
Water system SUPPLY
E – connection M ½ “
Water drain in overpress. – temp.
F – connection M ¾ “
Wood-burning
heating
chamber
1st CIRCUIT
heating
A - delivery M 1”
B
-
delivery M 1”
2nd CIRCUIT
DHW
C - delivery M ½ ”
D
-
delivery M ½ ”
(G)
External circuit to be created at the customer's premises
Vc = volume of water in combustion chamber
Vt = volume of water in pipes
Vv = volume of water in expansion tank Vv = 0.05 (Vc + Vt)
H > pump ( H greater than head h of circulating pump)
KEY - WOOD-BURNING STOVE SYSTEM
1) Drain cock 9) Filling cock or float valve
2) Heating chamber/circuit air vent 10) Heating chamber filling pipe 1”
3) Thermal relief valve T>95°C 11) Safety and vent pipe 1”
4) Safety valve P max. 3 bar 12) Shutoff cock
5) Delivery manifold 1” 13) Electric circulating pump
6) Return manifold 1” 14) Non-return valve
7) System-door box (SA) Room temperature probe
8) Open expansion tank (ST1) delivery temperature probe
(ST
2) return temperature probe
KEY - DHW AND HEATING SYSTEM
(20) System shutoff cock (30) Boiler shutoff cock
(21) Filter in line (31) Water storage boiler 80-115 L
(22) Hydraulic manifold (32) Supplementary heater
(23) Zone solenoid valve (33) Filling and safety assembly
(24) Radiator (34) Distribution manifold
(25) Heating equipment (35) Sink with mixer
(ST1) zone temperature probe 1 (36) Bathtub with taps
(ST2) zone temperature probe 2 (37) Shower with mixer
(STB) Boiler temperature probe
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola Termo Diana at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola Termo Diana in the language / languages: English as an attachment in your email.

The manual is 1,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info