52 MEDEA – MEDEA LUX
ALARMS
-
MESSAGES
Signalling
Fault
Possible causes
Cures
AL 9
INSUFF
DRAUGHT
The combustion air flow has
dropped below a predefined
threshold
- The combustion chamber is
dirty
- The fume duct is blocked
- The fire door is not closed
- The overpressure valves are
open-jammed
- The air flow meter is dirty or
faulty
- Check the cleanness of the
flue pipe, the combustion
chamber and the air flow
meter; hermetic closure of the
door and the overpressure
valves. Then repeat the
lighting procedure
- Other reinstatement
operations must be carried out
by a service centre
AL b
AUG TRIAC
ERROR
Occurs when the gearmotor
runs continuously
- Incorrect parameters entered
- Faulty main board
Reinstatement operations
must be carried out by a
service centre
AWAITING
COOL
Occurs on relighting the stove
immediately after turning it off
Stove still too hot to start a
lighting phase
Wait for the stove to cool and
repeat the lighting procedure
AIR FLOW
METER
FAILURE
Occurs when the air flow
meter is disconnected. The
control does not detect the
amount of combustion air and
does not shut down the stove
The air flow meter connection
cable has been disconnected
The stove continues its normal
operation and safety is
guaranteed by the remaining
devices. It is advisable to
contact a service centre
as soon as possible
SERVICE
DUE
Occurs when the stove has
exceeded the hours of
operation since the previous
service
The stove requires
extraordinary maintenance
The stove continues its normal
operation. It is advisable to
contact a service centre
as soon as possible
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola Medea at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola Medea in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info