If the flue is not perpendicular to the chimney it is advisable to make the connection with special steel fittings that
allow a maximum slope of 45°.
If the walls and ceiling are made of flammable materials, the parts in contact with the flue must be suitably
insulated. All connection joints must be carefully sealed, in particular where the connection enters the flue.
If there are several heating stoves in the same home, each must have its own flue. It is inadvisable to make
openings in the flue for other appliances, since the draught could be negatively affected.
According to Standard UNI 7429, the chimney cap must meet several requirements; above all, it must have a
useful outlet cross section at least double that of the flue. It is also
advisable to install an "antiwind" cap that guarantees fume exhaust even
in the presence of strong horizontal winds.
NO YES YES
YES NO
Fig. 4 Chimney caps
3 – STOVE USE
3.1 Introduction
Never leave children unsupervised in the vicinity of the stove; the risk of burns caused by the hot parts is very
high.
Carefully observe the following rules:
- never use the stove with the door open;
- do not keep firelighters or easily flammable materials near the stove;
- do not move or lift the stove using the handles.
3.2 Adjusting the combustion air
Primary air:
the primary air is adjusted using the manual revolving controls on the firebox door, and feeds the fire through the
grate.
Secondary air:
the secondary air enters the stove by means of the sliding control located above the firebox door.
Optimum combustion conditions exist when, on loading wood, the combustion air feeds the flame by entering
through the grille, whereas the secondary air, entering through the control, enables the completion of combustion
in the upper part of the firebox.
3.3 Start-up
With first start-up, bad odours may be created, therefore air the room thoroughly especially when lighting the
stove the first time.
When lighting the stove the first time, allow it to burn with a low flame for several hours (primary air control open
30%).
The heat can then be increased a little at a time, so that the stove expands slowly and the paint and putty dry.
3.4 Lighting and controlling the fire
To light the fire it is advisable to use kindling and newspaper, or other means available on the market (excluding
any solid or liquid flammable and/or explosive substance).
The air control on the door, in the ash zone, must be open and is for adjusting stove heat output after the lighting
stage.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola Betty at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola Betty in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info