538265
7
Zoom out
Zoom in
Previous page
1/11
Next page
9
8
WARNING You may observe a spark when making
the connection because current can flow to charge
the capacitors in the inverter. Do not make this
connection in the presence of flammable fumes.
Explosion or fire may result. Thoroughly ventilate
the battery compartment before making this
connection.
3. Connect cable to the power source:
a. Connect the cable from the Negative (Black)
Terminal of inverter to the Negative Terminal
of the power source. Make a secure connection.
b. Connect the cable from the Positive (Red) Terminal
of the inverter to the Positive Terminal of the power
source (the batterys main fuse or the battery
selector switch, if you are using one). Make a
secure connection.
You might observe a spark when you make this connection
since current can flow to charge capacitors in the inverter.
All power connections to your Cobra inverter must
be Positive to Positive and Negative to Negative.
CAUTION Do not connect the inverter and another
AC source (such as a generator or utility power)
to the AC wiring at the same time. The inverter
will be damaged if its output is connected to
AC voltage from another source. Damage can
even occur if the inverter is switched off.
CAUTION Do not connect the inverter to an AC
branch circuit that has high-power consumption loads.
It will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume
more than 400 watts.
CAUTION Loose connectors result in excessive
voltage drop and may cause over heated wires
and melted insulation.
CAUTION Reverse polarity connections (positive
to negative) will blow external fuse in the inverter
and may permanently damage the unit. Such
damage is not covered by the warranty.
CAUTION Remove any jewelry (watch, ring, etc.).
Be careful not to short circuit the battery with
any metallic object (wrench, etc.).
WARNING 115 volt AC power is potentially lethal.
Do not work on AC wiring when it is connected to
the inverter (even if it is switched off) unless the
DC power source is physically disconnected from
the inverter. Also, do not work on AC wiring if it is
connected to another AC power source such as
a generator or the utility line.
WARNING You may observe a spark when making
the connection because current can flow to charge
the capacitors in the inverter. Do not make this
connection in the presence of flammable fumes.
Explosion or fire may result. Thoroughly ventilate the
battery compartment before making this connection.
Connecting Cables Connecting Cables
Installation Installation
Nothing Comes Close to a Cobra
®
Connect Power Source
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cobra CPI 480 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cobra CPI 480 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info