WARNING Power inverters contain components
that can produce arcs or sparks. To prevent fire
or explosion, do not install the inverter in areas or
compartments containing batteries or flammable
materials or in locations that require ignition-
protected equipment.
WARNING To reduce the risk of fire, do not cover
or obstruct the ventilation openings. Do not install
inverter in zero-clearance compartment.
Warning: Wash Hands After Handling Power Cord
The power cord on this product contains lead, a chemical
known in the state of California to cause birth defects or
other reproductive harm.
Caution: Rechargeable Appliances
Certain chargers for small nickel cadmium batteries can be
damaged if connected to the Cobra 400 watt inverter. Two
particular types of equipment are prone to this problem:
1. Small battery-operated appliances
such as flashlights, razors, and
night lights that can be plugged
directly into an AC receptacle to
recharge.
2. Certain battery chargers for
battery packs used in hand power
tools. These chargers have a
WARNING label stating that
dangerous voltages are present
at the battery terminals.
This problem does not occur with the vast majority of
battery operated equipment. Most use a separate charger
or transformer that is plugged into the AC receptacle and
produces a low voltage output. If the label on the AC
adapter or charger states that it produces a low voltage
AC or DC output (less than 30 volts), the inverter will
have no problem powering the adapter safely.
Plug In Directly
Dangerous Voltages
3
2
Important Safety Information
Introduction
Cobra 400 Watt Output Waveform
Some very sensitive electronic equipment may not operate
satisfactory on square wave” or “modified sine wave.”
The output waveform is referred to as “square wave” or
“modified sine wave.” It is a stepped waveform designed to
have characteristics similar to the sine wave shape of utility
power. A waveform of this nature is suitable for most AC
loads (including linear and switching power suppliers used
in electronic equipment, transformers and motors).
Quick Evaluation Before Installation
This section provides you with basic information about the
inverter and how to check its performance before installation.
Be sure to have on hand:
A 12 volt DC power source (such as a vehicle battery).
The power source must provide
between 11 and 15 volts DC and
be able to supply enough current to
run the test load. As a rough guide,
divide the wattage of the test load by
10 to get the current (in amperes)
the power source must deliver.
The provided two foot cigarette lighter cable and
two foot direct-to-battery 12 gauge cable.
Only use the cables provided with your inverter.
The cigarette lighter cable is suitable for operating the
inverter at loads up to 150 watts. Connect by securely
inserting the plug into the cigarette lighter socket.
CAUTION Do not use the cigarette lighter cable
for loads higher than 150 watts. When connecting
loads larger than 150 watts, please connect the
inverter directly to the battery.
Quick Evaluation
Before Installation
Introduction
Power Supply
Cig. Lighter Cable 12 Gauge Cable
Nothing Comes Close to a Cobra
®
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cobra CPI 480 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cobra CPI 480 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info