684051
42
Zoom out
Zoom in
Previous page
1/52
Next page
42
Fragrance pump M1 and M2 (230VAC)
The fragrance pumps are connected to the appropriate terminals of terminal
bloc “X22” on the steam bath board according to the wiring diagram. The
connection layout is dependent on the operating mode (internal or external
control) of the fragrance pumps.
The cross-section of the connecting cable must comply with the applicable
local regulations.
Steam bath lighting H2 and H3
The steam bath lighting (Light 1 and Light 2) is connected to the appropriate
terminals of terminal bloc “X21” on the steam bath board according to the
wiring diagram. The voltage supply of the steam bath lighting is made depend-
ent on the used illuminant either via the internal 230 VAC supply or via the
optional transformers T1 (230V/24V), T2 (230V/12V) or T3 (230V/24V)
The cross-section of the connecting cables must comply with the applicable
local regulations.
230 V voltage supply 12 V voltage supply
N
N
PE
L1
L1
Q9
230 V/1~/50..60 Hz
L N PE
F9
XE3
230V
12V 12V
230V 230V
230V
max. 2m
L N
8 A 250 VAC
8 A 250 VAC
X27
FAN 0V
LIGHT SUPPLY OUT
J2
EXT. TRAFO IN
24V 0V18V15V
X21
L NN LL N
LIGHT 1 LIGHT 2LIGHT IN
F5
230V: 1AT
24V: 4AT
12V: 6.3AT
T4
T4
H3
H2
H3
H2
T1
N
N
PE
L1
L1
Q9
230 V/1~/50..60 Hz
L N PE
F9
XE3
Supply FAN
(Light 24 V)
24V
24V
24V
18V
230V
L N
15V
0V
8 A 250 VAC
8 A 250 VAC
X27
FAN 0V
LIGHT SUPPLY OUT
J2
EXT. TRAFO IN
24V 0V18V15V
X21
L NN LL N
LIGHT 1 LIGHT 2LIGHT IN
F5
230V: 1AT
24V: 4AT
12V: 6.3AT
T2
Premium Pro
ext.
Premium Pro
ext.
N
N
PE
L1
L1
Q9
230 V/1~/50..60 Hz
L N PE
F9
XE3
12V
12V
L N
230V 12V
8 A 250 VAC
8 A 250 VAC
X27
FAN 0V
LIGHT SUPPLY OUT
J2
EXT. TRAFO IN
24V 0V18V15V
X21
L NN LL N
LIGHT 1 LIGHT 2LIGHT IN
F5
230V: 1AT
24V: 4AT
12V: 6.3AT
H3
H2
T3
Premium Pro
ext.
N
N
PE
L1
L1
Q9
230 V/1~/50..60 Hz
L N PE
F9
XE3
24V
24V
L N
230V 24V
8 A 250 VAC
8 A 250 VAC
X27
FAN 0V
LIGHT SUPPLY OUT
J2
EXT. TRAFO IN
24V 0V18V15V
X21
L NN LL N
LIGHT 1 LIGHT 2LIGHT IN
F5
230V: 1AT
24V: 4AT
12V: 6.3AT
H3
H2
Premium Pro
ext.
24V
H3
H2
24 V voltage supply (variant 1) 24 V voltage supply (variant 2)
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cleopatra Cleo Premium Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cleopatra Cleo Premium Pro in the language / languages: English as an attachment in your email.

The manual is 7,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info