133738
20
Zoom out
Zoom in
Previous page
1/22
Next page
ENGLISH
ENGLISH
20
ENGLISH
Cleaning
Cleaning the Air Filters
Always remove the mains plug before cleaning the device.
The air fi lters should be cleaned regularly by rinsing out under
running water. Pull out the air fi lters as shown in Fig. 7.
Fig. 7
Allow the fi lters to dry before you reinstall them.
Clean the air slits on the sides regularly with a vacuum
cleaner.
Reinstall the lters, ensuring that they are inserted correctly
into the slide mounting.
CAUTION:
The protective lter must always be inserted during
operation.
The device and housing should only be cleaned with a
slightly damp cloth.
Do not use any strong detergents or solvents for cleaning.
Troubleshooting
You should not try
ner
yourself. Improper repairs mean that the guarantee is
to repair or dismantle the air-conditio
no
longervalid and place the user and other property in danger.
Problem Cause Solution
The device does
not work
or does not provide
suf cient cooling
No power supply Check the mains
connection
Timer function is
activated
Deactivate the
timer function
Windows or doors
are open, there are
many people or a
source of heat in
the room
Close the doors
and windows
Dirty fi lters Clean the fi lters
Air infl ow or outfl ow
blocked
Remove the
blockage
Room temperature
is lower than the
set value
Change the tempe-
rature selection
The device is too
loud
It is not standing
upright
Place it on a fl at,
solid surface
Control lamp „
(K) lights up
Condensation
container is full
Empty the contai-
ner (see section
on „Emptying the
Water Container“)
Noise Emissions
The noise emission value in the workplace is less than 70 dB(A).
Technical Data
Model:............................................................................... CL 3134
Power supply:............................................................230 V, 50 Hz
Power consumption:............................................................ 800 W
Protection class:........................................................................... Ι
Energy effi ciency class: .............................................................. A
Protection class:.....................................................................IP20
Cooling capacity:...............................................................2050 W
Refrigerant: ............................................................. R410A (420g)
Air circulation:.........................................................up to 440 m³/h
Net weight: ........................................................................28,6 kg
This device has been tested according to all relevant current
CE guidelines, such as electromagnetic compatibility and low
voltage directives, and has been constructed in accordance with
the latest safety regulations.
Subject to technical changes without prior notice!
Guarantee
The device supplied by our Company is covered by a 24 month
guarantee starting on the date of purchase (receipt).
During the life of the guarantee any fault of the device or its
accessories ascribable to material or manufacturing defects will
be eliminated free of charge by repairing or, at our discretion, by
replacing it. The guarantee services do not entail an extension
of the life of the guarantee nor do they give rise to any right to a
new guarantee!
Proof of the guarantee is provided by the proof of purchase.
Without proof of purchase no free replacement or repair will be
carried out.
If you wish to make a claim under the guarantee please return
the entire machine in the original packaging to your dealer
together with the receipt.
Defects to consumables or parts subject to wearing as well as
cleaning, maintenance or the replacement of said parts are not
covered by the guarantee and hence are to be paid!
The guarantee lapses in case of unauthorized tampering.
05-CL 3134 20 14.12.2007, 14:17:39 Uhr
The narrow fi lter is inserted on the left-hand side. Push the wide
air lter on the right-hand side
into the front guide rail.
CAUTION:
Do not use the rear guide rail. This is where the tempera-
ture sensor is located, which could be damaged.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Clatronic cl 3134 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Clatronic cl 3134 in the language / languages: English, German, Italian as an attachment in your email.

The manual is 5,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Clatronic cl 3134

Clatronic cl 3134 User Manual - Dutch - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info