Configuring the Voice Settings
Regional
Cisco SPA100 Series Administration Guide 71
1
Ring and Call Waiting Tone Spec
IMPORTANT: Ring and Call Waiting tones do not work the same way on all phones. When
setting ring tones, consider the following recommendations:
Begin with the default Ring Waveform, Ring Frequency, and Ring Voltage.
If your ring cadence doesn’t sound right, or your phone doesn’t ring, change the
following settings:
- Ring Waveform: Sinusoid
- Ring Frequency: 25
- Ring Voltage: 80
Ring6 Name Name in an INVITE’s Alert-Info Header to pick distinctive ring/
CWT 6 for the inbound call.
Default setting: Bellcore-r6
Ring7 Name Name in an INVITE’s Alert-Info Header to pick distinctive ring/
CWT 7 for the inbound call.
Default setting: Bellcore-r7
Ring8 Name Name in an INVITE’s Alert-Info Header to pick distinctive ring/
CWT 8 for the inbound call.
Default setting: Bellcore-r8
Field Description
Ring Waveform Waveform for the ringing signal. Choices are Sinusoid or
Trapezoid.
Default setting: Trapezoid
Ring Frequency Frequency of the ringing signal. Valid values are 15–50 (Hz)
Default setting: 20
Ring Voltage Ringing voltage. Choices are 30–90 (V)
Default setting: 85
CWT Frequency Frequency script of the call waiting tone. All distinctive CWTs are
based on this tone.
Default setting: 440@-10
Field Description
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cisco Cisco SPA112 VoIP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cisco Cisco SPA112 VoIP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info