500804
13
Zoom out
Zoom in
Previous page
1/52
Next page
13
12
Manufacturer's Handbook and Declaration – Electromagnetic Emissions
The Chicco piston aerosol can be used in the electromagnetic environment specified below. The customer or
user of the aerosol unit must ensure it is used in such an environment
Emissions Tests Compliance Guide to electromagnetic environments
CISPR 11 Radiated/Con-
ducted Emissions
Group 1 The Chicco piston aerosol only uses RF energy
for its internal functions. Therefore its RF emis-
sions are very low and do not cause any interfer-
ence when in proximity to electronic devices.
CISPR 11 Radiated/Con-CISPR 11 Radiated/Con-
ducted Emissions
Class [B]
The Chicco piston aerosol is suited for use in
all environments, including those domestic and
those directly connected to the public electricity
distribution line that provides power to buildings
used for domestic purposes.
Harmonics
IEC/EN 61000-3-2
Class [A]
Voltage fluctuations/flickers
IEC/EN61000-3-3
[Compliant]
Manufacturer's guide and declaration – Electromagnetic Immunity
The Chicco piston aerosol can be used in the electromagnetic environment specified below. The customer or
user of the aerosol unit must ensure it is used in such an environment.
Emissions Tests Compliance Guide to electromagnetic environments
Electrostatic dis-
charges (ESD)
IEC/EN61000-4-2
±6kV on contact
±8kV in air
Floors should be made of wood, cement or ceramic. If the
floors are covered with synthetic material, the relative humid-
ity should be now higher than 30%
Fast/burst transients
IEC/EN61000-4-4
±2kV power The power supply should be that typical of a commercial
building or hospital.
Surge
IEC/EN61000-4-5
±1kV differential mode The power supply should be that typical of a commercial
building or hospital.
Voltage dips, brief
interruptions and
variations in voltage
IEC/EN61000-4-11
<5%UT for 0.5 cycle
40%UT for 05 cycle
70%UT for 25 cycle
<5%UT
for 5 sec
The power supply should be that typical of a commercial
building or hospital. If the aerosol user requires that the unit
operate continuously, it is recommended that it be used with
a UPS device.
Magnetic field
IEC/EN61000-4-8
3A/m The magnetic field should be that typical of a commercial
building or hospital.
Conducted Immunity
IEC/EN61000-4-6
3Vrms 150kHz to
80MHz (for non-life
supporting devices)
Radiated Immunity
IEC/EN61000-4-3
3V/m 80MHz to
2.5GHz (for non-life
support devices)
Note: UT is the value of the power voltage
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chicco Aerosol met Zuiger at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chicco Aerosol met Zuiger in the language / languages: English, German, Dutch, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email