OVERNIGHT BURNING
SPECIAL POINTS WHEN
BURNING WOOD
MAINTENANCE
For overnight burning the fire doors must be closed. Use large logs
rather than small ones.
If the fire is very low, it may be necessary to add a little fuel and turn
the thermostat control up to maximum for a brief period until the
fire is burning brightly, before filling with fuel. When the new fuel has
ignited, the thermostat control should be turned down to the
required setting. If the central heating pump is off overnight then the
thermostat may be left at the same setting for both day and night
operation. If the central heating pump is on overnight, set the
thermostat control to give the required level of heating. Some
experimentation will be necessary to find the settings most suitable
for the particular fuel used and the draw on the chimney.
To revive the fire, add some small logs and open the thermostat
control to maximum. When the fire is burning well load on more fuel
as necessary and move the thermostat control to the desired setting.
The grate should be kept in the closed position and should not be
riddled until the ash becomes so deep that it begins to block the
passage of air into the firebox at the sides or back of the grate. When
this is the case do not remove all of the ash using the riddling
mechanism but keep a layer about half an inch thick as this enables
the wood to burn more effectively. When lighting the fire a few small
dry logs with a good amount of kindling will help to get the fire up to
temperature quickly.
The stove is finished with a high temperature paint which will
withstand the temperatures encountered in normal use. This may be
cleaned with a damp lint-free cloth when the stove is cold. Should re-
painting become necessary then special high temperature paints are
available from your supplier or from Charnwood.
The glass in the doors is a special ceramic glass which is able to
withstand high temperatures. Before cleaning the glass open the
doors and allow them to cool. Clean the glass using a damp cloth and
then wipe over with a dry cloth. Any stubborn deposits on the glass
may be removed with a proprietary stove glass cleaner or ceramic
hob cleaner. Some deposits on the glass may be burnt off simply by
Cleaning
Cleaning the Glass
running the fire at a fast rate for a few minutes. Do not use abrasive
cleaners or pads as these can scratch the surface which will weaken
the glass and cause premature failure. Aerosol spray cleaners should
not be used near the appliance whilst it is under fire.
If the fire is going to be out of use for a long period (for instance in
the summer) then to prevent condensation, and hence corrosion, the
air control should be left fully open and the fire doors left ajar. It is
also advisable to sweep the chimney and clean out the fire. Spraying
the inside of the doors and firebox with a light oil, such as WD40,
will also help to keep all internal parts working well.
After long periods where the fire has been out of use, the chimney
and appliance flueways should be cleaned before lighting.
For the fire to operate correctly it is important that the door seals
are in good condition. Check that they do not become worn or
frayed and replace them when necessary.
It is recommended that the fire is serviced once a year to keep it in
first class working order. After cleaning out the firebox thoroughly,
check that all internal parts are in good working order, replacing any
parts that are beginning to show signs of wear. Check that the doors
seals are in good condition and that the doors seal correctly. A
servicing guide is available on request. Repairs or modifications may
only be carried out by the Manufacturer or their approved agents.
Use only genuine Charnwood replacement parts.
It is important that the throat plate and all the stove flueways are kept
clean. They should be checked approximately once a week, by
looking up into the firebox for signs of soot or fly-ash on the throat
plate and at the sides of the firebox. If there are signs of a build up of
soot or fly-ash deposits then the fire must be let out in order to clean
the throat plate and flueways.
Before attempting to clean the throat plate and flueways ensure that
the fire is cold. Wear suitable gloves to prevent irritation from soot
deposits. To remove the throat plate lift the whole plate up until it
comes clear of the rear brackets, then swing the back edge forwards
and unhook(see Fig. 4).
When Not in Use
Door Seals
Servicing
THROAT PLATE AND
FLUEWAY CLEANING
OPERATING INSTRUCTIONS
®
charnwood
I S L A N D
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood Island 3B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood Island 3B in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Charnwood Island 3B

Charnwood Island 3B User Manual - Dutch - 17 pages

Charnwood Island 3B User Manual - Dutch - 17 pages

Charnwood Island 3B User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info