HANG THE OPENER –
The opener must be securely fastened to a structural support of
the garage.
Three representative installations are shown. Yours may be
different. Hanging brackets (1) should be angled (Figure A) to
provide rigid support. On finished ceilings, (Figure B) attach a sturdy
metal bracket (not supplied) (4) to a structural support before installing
the opener. For concrete ceiling mount, (Figure C), use concrete
anchors (5) provided.
On each side of opener measure the distance from the opener to the
structural support (or ceiling).
Cut both pieces of the hanging bracket to required lengths. Flatten one
end of each bracket and bend or twist to fit the fastening angles. Do
not bend at the bracket holes. Drill 4,5mm (3/16") pilot holes in the
structural supports (or ceiling). Attach flattened ends of brackets to
supports with wood screws (2).
Lift opener and fasten to hanging brackets with screw, lock washer
and nut (3). Check to make sure T-rail is centered over the door.
REMOVE 25mm (1") board. Operate door manually. If door hits the
rail, raise header bracket.
Grease the top and underside of rail surface on which the trolley
slides. A tube of grease is supplied.
ATTACH MANUAL RELEASE ROPE
& HANDLE –
Thread one end of rope (1) through hole in top of red handle so
"NOTICE" reads right side up as shown (3). Secure with an overhand
knot (2). Knot should be at least 25mm (1") from end of the rope to
prevent slipping.
Thread other end of rope through hole in release arm of the outer
trolley (4). Adjust rope length so that handle is 1,8m (6 feet) above the
floor. Secure with an overhand knot.
Note: If it is necessary to cut rope, heat seal cut end with a match
or lighter to prevent fraying.
CONNECT ELECTRIC POWER
TO AVOID INSTALLATION DIFFICULTIES, DO NOT RUN THE
GARAGE DOOR OPENER UNTIL INSTRUCTED TO DO SO.
Connect the opener to a mains which is properly EARTHED
according to the wiring instruction tag attached to power supply
cord (and as specified by local code).
Connect the door opener only to an outlet controlled by a double
pole switch.
INSTALL THE LIGHT –
Install a 40 watt maximum light bulb (1) in the socket as shown. The
light will turn on and remain lit for 4-1/2 minutes when power is
connected. After 4-1/2 minutes it will turn off.
Replace burned out bulbs with rough service light bulbs.
17
16
15
Wear protective goggles when working overhead to protect your
eyes from injury.
Disengage all existing garage door locks to avoid damage to the
garage door.
To avoid serious personal injury from entanglement, remove all
ropes connected to the garage door before installing the opener.
Installation of this product shall comply with ZH1/494, VDE 0700
Part 238, and VDE 0700 Part 1.
It is recommended that the opener be installed 2,1m (7 feet) or more
above the floor where space permits.
POSITION THE HEADER BRACKET –
The header bracket must be rigidly fastened to a structural
support of the garage. Reinforce the wall or ceiling with a
40mm (1-1/2") board if necessary. Failure to comply may result
in improper operation of safety reverse system.
You can attach the header bracket either to the header wall (1) or to
the ceiling (3). Follow the instructions which will work best for your
particular requirements.
With the door closed, mark the vertical centerline (2) of the garage
door. Extend line onto header wall above the door.
Open door to highest point of travel. Draw an intersecting horizontal
line on header wall 5cm (2") above high point to provide travel
clearance for top edge of door.
INSTALL THE HEADER BRACKET –
A. Wall Mount: Center the bracket (2) on the vertical guideline (1)
with the bottom edge of the bracket on the horizontal line (6)
(with the arrow pointing toward the ceiling).
Mark either set of bracket holes (4 or 5). Do not use the holes
designated for ceiling mount. Drill 4,5mm (3/16") pilot holes and
fasten the bracket with wood screws (3).
B. Ceiling Mount: Extend vertical guideline (1) onto the ceiling.
Center the bracket (2) on the vertical mark no more than 150mm (6")
from the wall. Make sure the arrow is pointing toward the wall.
Mark holes designated for ceiling mount only (4). Drill 4,5mm (3/16")
pilot holes and fasten the bracket with wood screws (3).
ATTACH T-RAIL TO HEADER BRACKET –
Position opener on garage floor below the header bracket. Use
packing material to protect the cover.
Note: To enable the T-rail to clear sectional door springs, it may be
necessary to lift opener onto a temporary support.
The opener must either be secured to a support or held firmly in place
by another person.
Raise T-rail until cable pulley and header brackets come together.
Join with clevis pin (1). Insert ring fastener (2) to secure.
POSITION THE OPENER –
Note: A 25mm (1") board (1) is convenient for setting an ideal
door-to-T-rail distance (unless headroom is not sufficient).
Raise the opener onto a stepladder. Open garage door. Place a
25mm (1") board (1) laid flat on the top section of door near the
centerline as shown. Rest the T-rail on the board.
If the raised door hits the trolley, pull down on the trolley release arm
to disconnect the inner and outer trolley sections. The trolley can
remain disconnected until connecting door arm to trolley is completed.
14
13
12
11
INSTALLATION SECTION
1911
3-GB
114A2360E
20


Need help? Post your question in this forum.

Forumrules
1

Forum

chamberlain-motorlift-1000

Reset search

  • tenho à vários anos um Chamberlain Motorlift 1000,só hoje é que deixou de trabalhar não obedece ao
    telecomando .Não sei o que aconteceu.Os telecomandos estão a funcionar bem.Será que a placa electrónica ou o motor estão avariados.Diga-me da sua Justiça.
    Nada mais tenho a dizer,envio meus cumprimentos. Submitted on 31-5-2021 at 17:52

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chamberlain Motorlift 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chamberlain Motorlift 1000 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info