667043
8
Zoom out
Zoom in
Previous page
1/36
Next page
8 I
Your Advanced VX tripod comes with the alignment peg
installed so the polar axis and counterweight bar extends
between two tripod legs. If you wish, you can reposition the
alignment peg so the counterweight bar extends directly
over a tripod leg. This is a matter of personal preference and
does not affect the stability of the mount. Observers at lower
latitudes will prefer to leave the alignment peg between two
legs to avoid the counterweight from making contact with the
tripod leg when the counterweight is in the lowest part of its
swing. To change the position of the alignment peg:
1. Use a wrench to hold the alignment peg in place while
using another wrench to loosen the locking nut under-
neath the alignment peg.
2. Once the nut is loose, you can unthread the alignment
peg and move it to the threaded hole on the opposite
side of the tripod head.
3. Thread the peg in until it stops, and back it off until the
flat sides of the alignment peg are square to the tripod.
4. Hold the peg in this position with one wrench while
using another wrench to tighten the locking nut against
the tripod head.
5. Mount the equatorial head as described above.
Attaching the Accessory Tray
The Advanced VX mount comes with an accessory tray
that has holes specially designed for 1.25” and 2” eyepieces.
The accessory tray also acts as a tripod leg tensioner to add
stability to the mount. To install the tray:
1. Remove the nut and washer from the lower side of the
tripod’s central rod.
2. Slide the accessory tray over the central rod so that
each arm of the tray is pushing against the inside of
the tripod legs.
3. Thread the accessory tray knob onto the central rod
and tighten.
Installing the Counterweight Bar
To properly balance the telescope, the mount comes
with a counterweight bar and at least one counterweight
(depending on model). To install the counterweight bar:
1. Locate the counterweight bar and locking nut from the
box containing the equatorial head. The locking nut
should already be threaded onto the end of the counter-
weight bar.
2. Locate the opening in the equatorial mount on the
declination axis and thread the counterweight bar into
the opening until it is tight.
3. Tighten the counterweight bar lock nut fully.
Once the bar is securely in place, you are ready to attach
the counterweight.
Observing Tip: Since the fully assembled telescope can
be quite heavy, position the mount so that the polar axis is
pointing towards north before the optical tube assembly and
counterweights are attached. This will make the polar
alignment procedure much easier.
Installing the Counterweight
To install the counterweight(s) that were included with your
mount or telescope kit:
1. Orient the mount so the counterweight bar points toward
the ground.
Central
Column
Lock Nut
Declination Axis
Counterweight Bar
Counterweight
Lock Screw
Counterweight
Safety
Screw
Accessory
Tray
Mounting Knob
Alignment Peg
Lock Nut
Tripod Head
Tray Knob
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Celestron Advanced VX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Celestron Advanced VX in the language / languages: English as an attachment in your email.

The manual is 5,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Celestron Advanced VX

Celestron Advanced VX User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info