740165
40
Zoom out
Zoom in
Previous page
1/58
Next page
3. Use (A) and (D) to move the pointer to
[BARO INFORMATION].
4. Press (C).
5. Use (A) and (D) to select a barometric
pressure change indicator setting.
[ON]
Enables the barometric pressure
change indicator.
[OFF]
Disables the barometric pressure
change indicator.
6. Press (C) to complete the setting
operation.
After the setting operation is complete,
[SETTING COMPLETED] will appear for
a few seconds, and then the Barometer/
Temperature Mode setting screen will re-
appear.
7. Press (E) to exit the setting screen.
Note
If the barometric change indicator is
enabled, readings are taken every two
minutes even while the watch is not in
the Barometer/Temperature Mode.
The barometric pressure change
indicator becomes disabled
automatically 24 hours after it is
enabled.
Power Saving is disabled while
barometric pressure trend information
is enabled.
l
Power Saving Function
The barometric pressure change
indicator will become disabled
automatically when the battery
becomes [CHG] or lower.
Calibrating Barometric
Pressure Readings
The watch’s pressure sensor is adjusted at the
factory and normally does not require
calibration. However, you can calibrate the
displayed value if you notice major errors in
readings.
Important!
The watch will not be able to produce
correct barometric pressure readings if
you make a mistake during the
calibration procedure. Check to make
sure that the value you use for
calibration produces correct pressure
readings.
1. Enter the Barometer/Temperature Mode.
l
Navigating Between Modes
2. Hold down (A) for at least two seconds.
This displays the Barometer/
Temperature Mode setting screen.
Pointer
3. Use (A) and (D) to move the pointer to
[CALIBRATION].
4. Press (C).
5. Use (A) and (D) to move the pointer to
[BAROMETER].
6. Press (C).
7. Use (A) and (D) to move the pointer to
[MANUAL].
Selecting [OFFSET OFF] returns
barometric pressure calibration to its
factory default state.
8. Press (C).
9. Repeat the steps below to change the
value.
Use (A) and (D) to change the
underlined value.
Use (C) to move the underlining to the
value you want to change.
To stop the setting operation, press (E)
and advance to step 11.
10. After all the values are the way you want,
press (C).
11. Use (A) and (D) to select whether or not
you want to save your current settings.
[YES] Saves current settings.
[NO] Discards current settings.
[RETURN]
Return to the barometric
pressure manual calibration
screen.
12. Press (C) to complete the setting
operation.
After the setting operation is complete,
[SETTING COMPLETED] will appear for
a few seconds, and then the calibration
method selection screen will re-appear.
13. Press (E) twice to exit the setting screen.
Operation Guide 3475
40
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio QW3475 - GBD-H1000 G-SQUAD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio QW3475 - GBD-H1000 G-SQUAD in the language / languages: English as an attachment in your email.

The manual is 4,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info