English
Command 4 – Conversion Equation Setup
{ 4, Equation Number, Equation Type, Number Format, Constants }
Equation Number Equation Type Number Format Constants
* 0 Clear All equations. * 0 Clear equation selected by the equation number parameter. ––– –––
1Equation 1 (Channel 1) 1 Polynomial K0 + K1X + K2X
2
+...+ KnX
n
*
1
* 0 Standard K0( ,K1,...,K9) *
3,4
2Equation 2 (Channel 2) 2 Mixed polynomial KmX
–m
+ ...+ K–1X
–1
+ KO + K1X +...+ KnX
n
*
2
10 Integer part (Decimal part cut off.) K–4( ,..., K–1, K0, K1, ..., K5) *
3,4
3Equation 3 (Channel 3) 3 Power K0 • X
(K1)
+ K2
4 Modified power K0 • K1
X
+ K2
5Logarithmic K0 + K1 In(X)
6 Modified logarithmic K0 + K1 In(1 / X)
7 Exponential K0e
(K1X)
+ K2 K0( , K1, K2, K3) *
3,4
8 Modified Exponential K0e
(K1/X)
+ K2
9 Geometric K0X
(K1X)
+ K2
10 Modified geometric K0X
(K1/X)
+ K2
11 Reciprocal logarithmic 1 / {KO + K1 In(K2X)} + K3
12 Steinhart-Hart 1 / {KO + K1(In 1000X) + K2(In 1000X)
3
} + K3
4Equation 4
(SONIC channel)
* 0 Clear equation 4
Unit Temperature
1 Temperature used by distance conversion expression * 0 °C(Celsius) Temperature
1 °F (Fahrenheit) ( *20)
2 °C (Celsius)
3K (kelvin)
4 °R (Rankin)
α-1-3
Channel Select Data Select Data Begin Data End Step K FFT Samples
* 0 Current send channel * 0 Raw data 1 to 120000 1 to 120000 Data Range Steps (*255) 1 to 14 : Samples used
1 Channel 1 1 d/dt (*1) * 0 : Last sample –1: Data range number / K (*6) 2
n
(2–16384)
2 Channel 2 2 d
2
/dt
2
(*1)
3 Channel 3 10 FFT-Real
4 SONIC channel 11 FFT-Imaginary
5DIG IN channel
6Recorded time data
10 Microphone
Command 5 - Data Range Setup
{ 5, Channel Select, Data Select, (FFT Samples,) Data Begin, Data End, Step, K }
20020701
*1
Polynomial: Input constants in sequence, from n = 0 to 9.
*2
Mixed polynomial: Input constants in sequence from m = 4 to 1, and n = 0 to 5.
*3
Input of zero for constants can be skipped if all remaining constants are not used.
*4
Input 0 for constants that are not used.
When the conversion result of the “conversion equation” selected by Command 4 causes an overflow, the EA-200 sends a result of zero (0) to the calculator.
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio EA200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio EA200 in the language / languages: English as an attachment in your email.

The manual is 2,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info