d Supplementary explanation of AT command
Commands which do not function
The following commands do not generate errors but will not function as a command:
ATT (Tone setting)
ATP (Pulse setting)
Command name: +CGDCONT=[parameter]
Outline
Sets the access point name (APN) for packet origination.
Though this command is a setting command, it will not be recorded in non-volatile memory written by [&W], nor reset
by [&F] or [Z].
Format
+CGDCONT=[ <cid>[ ,"<PDP_type>"[ ,"<APN>"] ] ]
Explanation of the parameters
Sets the access point name (APN) for packet origination. See the following command execution example:
<cid>
*1
1 ~ 10
<PDP_type>
*2
PPP or IP
<APN>
*3
Any value
*1<cid> is a number for managing the access point name (APN) registered in the FOMA terminal for a packet
communication. For the FOMA terminal, you can register from number 1 to 10. As "mopera.ne.jp" is assigned to
<cid>=1, "mopera.net" to <cid>=2 and 3, and <cid>=4 to "mpr.ex-pkt.net", respectively by default, assign the
APN to cid5 to cid10.
*2<PDP_type> is the connection method. For the FOMA terminal, you can specify PPP or IP. PPP is assigned to
<cid>=1 ,2 and 4, and IP is assigned to <cid>=3 by default. Specity PPP when you use the FOMA terminal as an
access point for Access point mode.
*3<APN> is an arbitrary character string indicating each access point name.
Operation performed when the parameter is omitted
+CGDCONT= Sets the initial value to all <cid>.
+CGDCONT=<cid> Sets the specified <cid> to the initial value.
+CGDCONT=? Displays a list of values that can be set.
+CGDCONT? Displays the current setting.
Command execution example
Command for registering an APN name of abc (when cid is 5).
AT+CGDCONT=5,"PPP","abc"
OK
Command name: +CGEQMIN=[parameter]
Outline
Registers a criterion to be used to decide whether or not to allow the QoS (quality of service) that is informed from the
network side when PPP packet communication is established.
There are 4 setting patterns as described in the following command execution example.
Though this command is a setting command, it will not be recorded in non-volatile memory written by [&W], nor reset
by [&F] or [Z].
Format
+CGEQMIN=[<cid>[ ,,<Maximum bitrate UL>[ ,<Maximum bitrate DL>] ] ]
Explanation of the parameters
<cid>
*1
1 10
<Maximum bitrate UL>
*2
None (initial value) or 5,760
<Maximum bitrate DL>
*2
None (initial value) or 7,232
*1<cid> is a number for managing the access point name (APN) registered in the FOMA terminal for a packet
communication.
*2<Maximum bitrate UL> and <Maximum bitrate DL> set the maximum communication speed (kbps) of uplink and
downlink between the FOMA terminal and base station. When it is set to "None" (initial value), all speeds will be
permitted, but when set to 5,760 or 7,232, a connection at a speed of other values will not be permitted, and a
packet communication may not be connected.
Operation performed when the parameter is omitted
+CGEQMIN= Sets the initial value to all <cid>.
+CGEQMIN=<cid> Sets the specified <cid> to the initial value.
+CGEQMIN=?Displays a list of values that can be set.
+CGEQMIN?Displays the current setting.
CA-01C_E_Manual_02.fm 48 ページ 2011年5月3日 火曜日 午後12時30分
159


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio CA-01C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio CA-01C in the language / languages: English as an attachment in your email.

The manual is 9,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info