481319
8
Zoom out
Zoom in
Previous page
1/45
Next page
4
m
m
The hexagon wrench
is required.
Packed valve handling precautions
Open the valve stem all the way out, but do not try to open it beyond
the stopper.
Securely tighten the valve stem cap with torque in the following table:
Wiring Connection
1. Remove the valve cover from the outdoor unit.
2. Connect the connecting cable to the terminals as identified with their
respective matched numbers on the terminal block of indoor and
outdoor unit.
3. When connecting the connecting cable to the outdoor unit terminals,
make a loop as shown in the installation diagram of indoor and
outdoor unit to prevent water coming in the outdoor unit.
4. Insulate the unused cords (conductors) from any water coming in the
outdoor unit. Proceed them so that they do not touch any electrical or
metal parts.
Stripping length of the connecting cable
CAUTION
Wrong wiring connection may cause some electrical parts burn out.
Be sure to comply with local cords on running the wire from indoor
unit to outdoor unit (size of wire and wiring method, etc.).
Every wire must be connected firmly.
This installation fuse (25A) must be used for the power supply line
of this air conditioner.
If incorrect or incomplete wiring is carried out, it will cause an
ignition or smoke.
Prepare the power supply for exclusive use with the air conditioner.
This product can be connected to the mains.
Connection to fixed wiring: A switch which disconnects all poles
and has a contact separation of at least 3 mm must be
incorporated in the fixed wiring.
NOTE : Connecting cable
Wire type : More than H07RN-F or 245 IEC66
Gas side 30 to 42 N·m
(9.52 mm) (3.0 to 4.2 kgf·m)
Liquid side 16 to 18 N·m
(6.35 mm) (1.6 to 1.8 kgf·m)
Service port
9 to 10 N·m
(0.9 to 1.0 kgf·m)
Gas Leak Test
Check places for
the outdoor unit.
Electric parts cover
Valve cover
Check the flare nut connections for the gas leak with a gas leak
detector or soap water.
OTHERS
Model 38VYX025-R 38VYX035-R
Power source 50/60 Hz, 220 – 240 V Single phase
Maximum running current 8A 11A
Plug socket & fuse rating 25A
Power cord H07RN-F or 245 IEC66 (1.5 mm
2
or more)
Check places for
the indoor unit.
When two indoor units are installed in the separated rooms, it
is not necessary to change the selector switches.
Remote control selector switch
When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may receive
the remote control signal simultaneously and operate. In this
case, the operation can be preserved by setting either one
indoor unit or remote control to B setting. (Both are set to A
setting in factory shipment.)
The remote control signal is not received when the settings of
indoor unit and remote control are different.
There is no relation between A setting/B setting and A room/B
room when connecting the piping and cables.
Setting of Remote Control
Selector Switch
10
L3N
30
10
40
Connecting cable
Earth line
GB - 4
1
2
3
LN
Connecting cable
Earth lin
e
Terminal block
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carrier 42ADF025 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carrier 42ADF025 in the language / languages: All languages as an attachment in your email.

The manual is 2,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Carrier 42ADF025

Carrier 42ADF025 User Manual - English, Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info