Magic 1000 N000925 12/2010 9 / 214
knowledge of the door operator is to use the device, they
must be supervised by a person who assumes
responsibility for their safety.
Installation must be performed by qualified service
technician.
Work on the electrical installation must only be carried out by
authorised specialist personnel.
The load capacity and suitability of the supporting
construction of the building in which the door operator is to be
installed must be inspected and approved by an expert.
The door operator must be fully and securely attached at all
fastening points. All fastening materials must be selected
according to the nature of the supporting construction and
they must be able to withstand traction force of 900 N.
In the event of non-conformance with these
requirements, there is a risk of injury and material
damage caused by a falling operator or an uncontrolled
movement of the door.
When drilling the fastening holes, do not damage the building
structure or any electrical, water or other lines.
After lifting up the door operator to the ceiling, fasten it fully
with appropriate tools to prevent it from falling down. See
illustration on page 166.
Please observe appropriate industrial safety regulations and
keep children away during installation.
The door operator has the following safety devices. Do
not remove them or alter their functionality.
Automatic load switch-off during functions "OPEN" and
"CLOSE"
Connection for photo cell / safety rail / optosensor
EMERGENCY stop connection: Connection of a switch
(optional) to an inset door mounted in the garage door, for
example
Emergency release (see page 168 (J))
Checking load switch-off
The automatic load switch-off is a clamping and safety
mechanism that is designed to prevent accidents due to a
moving door.
Stop the door from outside with both hands at waist height.
When closing:
The door must stop automatically and reverse a little if it
comes into contact with an obstruction.
When opening:
The door must stop automatically when it meets with
resistance (if menu A7 = 001, it moves back a short distance).
After load switch-off, the door operator lights flash until the
next pulse or wireless command is received.
Emergency release
Check as per the information provided on page 168 (J).
Additional safety devices
Check for proper functioning as per the manufacturer’s
instructions.
Messages of the indicator lamp (8)
7 Installation precautions
8 Safety devices of the door operator
9 Safety inspection
10 Controls and indicators
5 Pushbutton Close door / Minus
6 Pushbutton Menu / Confirm (Teach-in run)
7 Pushbutton Open door / Plus
8 Indicator lamp
Status messages
A door in end position OPEN
B door between the two end positions
C door in end position CLOSED
Status messages
During door movement in OPEN direction
C => B => A...
During door movement in CLOSE direction
A => B => C...
L4 Set end position OPEN
L3 Reference run CLOSE and set end position CLOSED
L2 Teach-in run OPEN (load values)
L1 Teach-in run CLOSE (load values)
Err Error and error number (flashing)
11 Connections
1 EMERGENCY stop (green)
2 Photo cell (yellow)
3
Function programmable, see Chapter 18, C4
4
567
8
1342
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cardo Door Magic 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cardo Door Magic 1000 in the language / languages: All languages as an attachment in your email.

The manual is 6,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info