Immunity test IEC 60601 level test Compliance level Electromagnetic environment- guidelines
NOTE 1: For 80 MHz and 800 MHz is applicable the highest frequency range.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic multiplication is not influenced by absorption and
reflection from structure, objects and people.
а
The strength of the field from stationary transmitters, as main situations for radio (cellular/wireless)
telephones and terrestrial mobile radios, amateur radio, АМ and FM broadcasting and TV broadcasting,
theoretically it can not be provided with accuracy. To evaluate the electromagnetic environment,
because of fixed radiofrequency transmitters, it have to be provided survey of electromagnetic objects.
If the measured power of the field, on which JXB-183 is used, increases the applicable compliance level
with RF above, medical JXB-183
must be monitored, to check the normal working. If observed
abnormal performance, additional measures must be taken,
as reorientation or moving of JXB-183.
b At frequency, higher than the range 150 KHz to 80 MHz, the strength of the field must be less than 3 V/m.
Recommended distances for separating between portable and mobile RF equipment and the medical “JXB-183”
“JXB-183” is intended for using in electromagnetic field, in which the emitted RF interruptions are controlled. The client or
user of the medical “JXB-183” can help for preventing the electromagnetic interruptions, as it keeps to the minimal distances
between portable and mobile RF communication equipment (transmitters) and “JXB-183” , as the recommended below,
according maximal power of the communication equipment.
The calculated
maximum output
power of the
transmitter
Separation distance, according the frequency of transmitter.
150 KHz to 80 MHz
d = [ 3,5/V1] VP
80 MHz to 800 MHz
d = [ 3,5/E1 ] VP
800 MHz to 2,5 GHz
d = [ 7/E1 ] VP
0,01 / 0,12 0,23
0,1 / 0,38 0,73
1 / 1,2 2,3
10 / 3,8 7,3
For transmitters, calculated with maximal output power, which are not recorded above, the recommended separating
distances d in meters (m) can be predicted, using the equal, applicable to the transmitter’s frequency, where P is the
maximum output power, measured in vats (W), according to the manufacturer’s transmitter.
NOTE 1: For 80 MHz and 800 MHz, the separating distance for the higher frequency range applies. NOTE 2: This guideline
may not apply in all situations. The electromagnetic multiplication is influenced by absorption from structures, objects and
people.
Produced for CANGAROO in China
Manufacturer: Guangzhou Jinxinbao Electronic Co., Ltd.
Address: 38 Huanzhen Xi Road Dagang Town, Nansha, Guangzhou, China
Importer: Moni Trade ltd.
Address: Bulgaria, Sofia, Trebich quarter, ul. Dolo 1
Tel.: 02/ 936 07 90
DE
DER HERSTELLER BEHÄLT SICH DAS RECHT VOR, DIE PRODUKTSPEZIFIKATIONEN OHNE WARNUNG ZU
ÄNDERN!
WICHTIG! LESEN SIE SORGFÄLTIG UND BEHALTEN SIE FÜR ZUKÜNFTIGE REFERENZEN!
EMPFEHLUNGEN UND HINWEISE FÜR SICHERE VERWENDUNG
- Befolgen Sie die in der Anleitung beschriebenen Wartungshinweise.
- Das Gerät darf für den professionellen oder persönlichen Gebrauch verwendet werden.
- Das Gerät muss für die in diesem Handbuch beschriebenen Zwecke verwendet werden.
- Dieses Gerät soll nur in einem Umgebungstemperaturbereich von 10 bis 40 Grad verwendet werden.
- Das Gerät ist nicht für Verwendung von Kindern geeignet. Medizinprodukte sind kein Spielzeug!
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cangaroo JXB-183 Easy Check at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cangaroo JXB-183 Easy Check in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 3,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info