764897
22
Zoom out
Zoom in
Previous page
1/24
Next page
THUNDER BAY SE
Display Messages
Heater Flow is Reduced (HFL) – M016
There may not be enough water  ow through the heater to
carry the heat away from the heating element. Heater start up
will begin again after about 1 min. See “Flow Related Checks”
below.
Heater Flow is Reduced (LF)* – M017
There is not enough water ow through the heater to carry the
heat away from the heating element and the heater has been
disabled. See “Flow Related Checks” below. After the problem
has been resolved, you must press any button to reset and
begin heater start up.
Heater may be Dry (dr)* – M028
Possible dry heater, or not enough water in the heater to start
it. The spa is shut down for 15 min. Press any button to reset
the heater start-up. See “Flow Related Checks” below.
Heater is Dry* – M027
There is not enough water in the heater to start it. The spa is
shut down. After the problem has been resolved, you must
press any button to reset and restart heater start up. See “Flow
Related Checks” below.
Heater is too Hot (OHH)* – M030
One of the water temp sensors has detected 118°f (47.8°C)
in the heater and the spa is shut down. You must press any
button to reset when water is below 108°f (42.2°C). See “Flow
Related Checks” below.
A Reset Message may Appear with other Messages.
Some errors may require power to be removed and restored.
Flow-Related Checks
Check for low water level, suction ow restrictions, closed
valves, trapped air, too many closed jets and pump prime.
On some systems even when spa is shut down, some
equipment may occasionally turn on to continue monitoring
temperature or if freeze protection is needed.* This message
can be reset from the topside panel with any button press.
Sensor-Related Messages
Sensor Balance is Poor – M015
The temperature sensors MAY be out of sync by 2°F or 3°F.
Call for Service.
Sensor Balance is Poor* – M026
The temperature sensors ARE out of sync. The Sensor Balance
is Poor fault has been established for at least 1 hour.
Call for Service.
Sensor Failure – Sensor A: M031, Sensor B: M032
A temperature sensor or sensor circuit has failed. Call for Service.
Miscellaneous Messages
No Communications
The control panel is not receiving communication from the
System. Call for Service.
Pre-Production Software
The Control System is operating with test software. Call for Service.
°F or °C is replaced by °T
The Control System is in Test Mode. Call for Service. * This mes-
sage can be reset from the topside panel with any button press.
Heater-Related Messages
(22)
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Thunder Bay SE - KH-10030 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Thunder Bay SE - KH-10030 in the language / languages: English as an attachment in your email.

The manual is 11,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info