OKANAGAN/SASKATOON/GANDER/MUSKOKA SPAS
Meaning:
No message on display.
Power has been cut off to the spa.
Temperature unknown.
“Overheat” - The spa has shut down. One of the
sensors has detected 118°F/48°C at the heater.
“Overheat” - The spa has shut down. One of
the sensors has detected that the spa water is
110°F/43°C.
“Ice” - Potential freeze condition detected.
Spa is shut down. The sensor that is plugged
into the Sensor “A jack is not working.
Spa is shut down. The sensor that is plugged
into the Sensor “B” jack is not working.
Sensors are out of balance. If alternating with
spa temperature, it may just be a temporary
condition. If ashing by itself, spa is shut down.
A signicant difference between temperature
sensors has been detected. This could indicate a
ow problem.
Persistent low ow problems. (Displays on the
fth occurrence of HL message within 24
hours.) Heater is shut down, but other spa
functions continue to run normally.
Possible inadequate water, poor ow, or air
bubbles in detected in the heater. Spa is shut
down for 15 minutes.
Inadequate water detected in heater. (Displays
on third occurrence of dr message.) Spa is
shut down.
Action Required:
The control panel will be disabled until power returns. Spa
settings will be preserved until next power up.
After the pump has been running for 2 minutes, the
temperature will be displayed.
DO NOT ENTER THE WATER. Remove the spa cover and allow
water to cool. Once the heater has cooled, reset by pushing
any button. If spa does not reset, shut off the power to the spa
and call your dealer or service organization.
DO NOT ENTER THE WATER. Remove the spa cover and allow
water to cool. At 107°F/42°C, the spa should automatically
reset. If spa does not reset, shut off the power to the spa and
call your dealer or service organization.
No action required. The pump and blower will automatically
activate regardless of spa status.
If the problem persists, contact your dealer or service
organisation. (May appear temporarily in an overheat situation
and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat situation
and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organisation.
Check water level in spa. Rell if necessary. If the water level
is okay, make sure the pumps have been primed. If problem
persists, contact your dealer or service organization.
Follow action required for HL message. Heating capability of
the spa will not reset automatically; you may press any button
to reset.
Check water level in spa. Rell if necessary. If water level is
okay, make sure the pumps have been primed. Press any
button to reset, or this message will automatically reset within
15 minutes. If problem persists, contact your dealer or service
organisation.
Follow action required for dr message. Spa will not
automatically reset. Press any button to reset.
Message
--
HH
OH
IC
SA
Sb
Sn
HL
LF
dr
dy
(9)
Diagnostic Messages
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Muskoka at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Muskoka in the language / languages: English as an attachment in your email.

The manual is 3,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info