OKANAGAN/SASKATOON/GANDER/MUSKOKA SPAS
MVP260 Control Reference Card
Initial Start-up
When your spa is rst actuated, it will go into Priming mode, indicated by “ .” Please see the M-7 Installation Instruction Manual
for complete instructions on Power-up and Pump Priming. The Priming mode will last for less than 5 minutes (warm to skip
Priming Mode) and then the spa will begin to heat up and maintain the water temperature in the Standard mode.
Temp/Set (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100F°/37°C. The last
measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is
current only when the pump has been running for at least
2 minutes.
To display the set temperature, press the warm pad once.
To change the set temperature, press the pad a second time
before the LCD stops ashing. Each press of the “warm or cool
button pad will to either raise or lower the set temperature.
After three seconds, the LCD will stop ashing and display the
current spa temperature.
Jets
Touch the “Jets” button once to activate the low speed of the
pump and again for the high speed. Press the “Jets” button
again to turn off the pump. If left running, the low speed of
the pump will automatically turn off after 4 hours, and the high
speed will automatically turn off after 15 minutes. The low
speed of the pump runs when the blower is on. It may also
activate for at least 2 minutes every 30 minutes to detect the
spa temperature and then to heat to the set temperature if
needed, depending upon mode. When the low speed turns on
automatically, it cannot be deactivated from the panel;
however, the high speed may be started.
Light
Press the “Light” button to turn the light on and off. If left on,
the light automatically turns off after 4 hours.
Mode
Mode is changed by pressing the “warm” button, then pressing
the “Light” button.
Standard Mode is programmed to maintain the desired
temperature. Note that the last measured spa temperature
displayed is current only when the pump has been running for
at least 2 minutes. “ST ” will be displayed momentarily when
you switch into Standard Mode.
Economy Mode heats the spa to the set temperature only
during lter cycles. “EC” will display solid when temperature is
not current, and will alternate with temperature when
temperature is current.
Sleep Mode heats the spa to within 20°F/10°C of the set
temperature only during lter cycles. “SL ” will display solid
when temperature is not current, and will alternate with
temperature when temperature is current.
Preset Filter Cycles
The rst lter cycle begins 6 minutes after the spa is
energized. The second lter cycle begins 12 hours later. Filter
duration is programmable for 2, 4, 6, 8 hours or for continuous
ltration (indicated by “ ”). The default lter time is 2 hours.
To program, press “warm button then “Jets.” Press “warm to
adjust. Press “Jets” to exit programming.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C
within the heater, the pump and blower will automatically
activate to provide freeze protection. The equipment stays on
until 4 minutes after the sensors detect that the spa
temperature has risen to 45°F/7.2°C or higher. In colder
climates, an optional additional freeze sensor may be added
to protect against freeze conditions that may not be sensed
by the standard sensors. Aux freeze sensor protection acts
similarly except with the temperature thresholds determined by
the switch and without a 4-minute delay in turnoff. See your
dealer for details.
(8)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Muskoka at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Muskoka in the language / languages: English as an attachment in your email.

The manual is 3,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info