E - 2 - Setting temperature or power (Fig. 5)
Your appliance is equipped with a setting handle which
makes it possible to adjust the temperature radiated
by the catalytic panel depending on the temperature
desired in the room.
a) CR 5000 Version and CR 5000 Turbo Versions
- Set the heating temperature by positioning handle
index between positions (III) and (I)(3: see fig. 5 - CR
5000 - item A and - CR 5000 Turbo - item A)
EXCLUSIVE TO CR 5000 TURBO VERSION
After lighting up your appliance in compliance with the
indications of paragraph E-1, you can increase its
heating performance by means of the «Turbo» function.
The «Turbo» function provides for fast and even heating
of the room because it uses a tangential ventilation to
propel the hot air flow out of the appliance.
The «Turbo» function is turned on / off by pressing the
red button (fig. 5 - CR 5000 Turbo - item C).
CAUTION:
The appliance was designed to be supplied with a
230 V 50 Hz voltage.
Your installation must be equipped with a grounding
connection compliant with electrical systems
specifications in force.
b) CR 5000 Thermo Version
- Set the heating temperature by positioning handle
index between positions maximum (IIII) and
minimum (I) (see fig. 5 - CR 5000 Thermo - item C)
E - 3 - Shutting down the appliance
- close bottle cock and/or gas pressure reducing valve
handle.
THIS APPLIANCE IS EQUIPPED WITH AN
ATMOSPHERE ANALYSER DEVICE WHICH
AUTOMATICALLY TURNS OFF THE APPLIANCE
SHOULD THE ROOM CONTAIN TOO HIGH A
CARBON DIOXIDE PERCENTAGE (CO
2
).
IN THIS CASE, THOROUGHLY VENTILATE THE
ROOM, OTHERWISE THE APPLIANCE WILL NOT
RELIGHT.
F - REMOVING OR REPLACING THE GAS
BOTTLE
- Check that gas bottle cock and/or pressure reducing
valve handle is in the closed position.
- Open appliance rear plate (fig. 4 item B) and remove
the bottle from its housing, taking care not to pull or
bend the hose.
- Disconnect pressure reducing valve from gas bottle.
- Install the new gas bottle and carry out a leak test as
described under paragraphs D-1 and D-2.
G - STORAGE - SERVICING
1) Appliance
When it is not used, the appliance should remain open
and be stored in a dust-free place.
- Remove stains with soapy water, when the appliance
is cold. Wipe off with a cloth.
- Do not use abrasives which might damage the
paintwork.
- For heavy repairs, please call your vendor.
- The appliance must be periodically checked, more
particularly concerning condition of the connecting
hose.
2) Hose between the pressure reducing valve and
the appliance
- Periodically check hose for condition and replace it if
it displays ageing signs or cracks.
- The hose must be replaced by a new one of same
length and equivalent quality.
- The hose must be replaced in compliance with
the above-mentioned periodicity for the respective
countries.
- In France, if the expiry date printed on the hose is
reached, it must be replaced by a hose compliant
with the XP D 36-112 Standard.
- Comply with installation indications provided with
these new assemblies to be 0.50 m long, and with the
procedure described under paragraph C-2.
- If your appliance is to remain unused for a long
period, disconnect gas bottle.
3) Electric supply cable (CR 5000 Turbo model)
- All damaged cables must be replaced by the
manufacturer, its after-sales service or a similarly-
qualified person, to avoid danger.
GB
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Campingaz CR 5000 Turbo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Campingaz CR 5000 Turbo in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info