810681
12
Zoom out
Zoom in
Previous page
1/16
Next page
min
9. Temperature curves for fuel gases
12
Flue draught 12 -16 Pa. Connect to upper flue outlet
Temperature change in buffer storage tank
Model Profi W 7
3 firings:
1. Charge 8 kg beech, 3% residual moisture, 50 mins
duration.
2. Charge 5 kg beech, 3% residual moisture, 50 mins
duration.
3. Charge 5 kg beech, 3% residual moisture, 50 mins
duration.3 firings:
Model Profi W 7
Base heat in buffer: T = 33 °C
Model Profi W 12
3 firings:
1. Charge 10 kg beech, 3% residual moisture, 70 mins
duration.
2. Charge 7 kg beech, 3% residual moisture, 70 mins
duration.
3. Charge 7 kg beech, 3% residual moisture, 50 mins
duration.
Model Profi W 12
Base heat in buffer: T = 33 °C
t°C t°C
500 500
400 400
300 300
200 200
100 100
0 0
0 030 3060 6090 90120 120150 150180 180
min
min min
min
Flue gas downstream
from water (with reversing
stone) Average: 240° C
Flue gas downstream
from water (with
reversing stone)
Average: 270° C
Flue gas with side outlet
(without reversing stone)
Average: 420° C
Flue gas with side outlet
(without reversing stone)
Average: 390° C
80 80
70 70
60 60
50 50
40 40
30 30
20 20
t°C t°C
0 030 30
60 60
90 90120 120150 150180 180
min
Boiler stove Buffer centre Pump
Buffer top Buffer bottom
Water exchanger
Buffer top
Buffer centre
Buffer bottom
10. Specifications
13
ProfiW 7 12
Rated output *) 12 14,9 kW
Water side/air side 70/30 70/30 %
Allowable working pressure 2 2 bar
Allow feed temperature 98° 98° C
Maximum working temperature 90° 90° C
Minimum feed temperature 65° 65° C
Minimum return temperature 55° 55° C
Volume 50 80 l
Weight (empty) 200 240 kg
Flue gas temperature *) 250° 300° C
Flue gas temperature **) 420° 390° C
Required draught *) 12 12 Pa
Efficiency > 80 > 80 %
*) The data given represent average values above a firing in the
completely submerged heating insert. That is, they result when a fuel
charge of approximately 8 kg of wood per charge is fired with fully
opened combustion air channel.
**) Flue gas temperature with side outlet (without reversing stone).
The data given represent average values above a firing in the
completely submerged heating insert.
The boiler stove can be connected on either the left or the
right.
The connection apertures that are not required can be
sealed with the cover and screw fastener provided.
It is recommended that the vent at connection 4 be
executed using both an automatic vent (TACO/HYVENT)
and with a lateral manual 3/8" vent valve at the T-piece.
The control thermostat switches the pump on to conduct
the heat energy away.
Warning:
This device is a hot water generator and is not subject
to steam boiler regulations!
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camina-Schmid Profi W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camina-Schmid Profi W in the language / languages: English as an attachment in your email.

The manual is 1.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Camina-Schmid Profi W

Camina-Schmid Profi W User Manual - German - 44 pages

Camina-Schmid Profi W User Manual - Dutch - 28 pages

Camina-Schmid Profi W User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info