752402
34
Zoom out
Zoom in
Previous page
1/44
Next page
34 1005494 ISSUE 5
OWNER/INSTALLATION MANUAL
5�3 FAULT CODES
No Display Description of fault code
1 E1 High pressure alarm
2 E2 Low pressure alarm
4 E7 Water outlet temp out of range alarm
5 E8 High exhaust temp alarm
6 EA Evaporator overheat alarm (only in cooling mode)
7 P0 Controller communication failure
8 P1 Water inlet temp sensor failure
9 P2 Water outlet temp sensor failure
10 P3 Gas exhaust temp sensor failure
11 P4 Evaporator coil pipe temp sensor failure
12 P5 Gas return temp sensor failure
13 P6 Cooling coil pipe temp sensor failure
14 P7 Ambient temp sensor failure
15 P8 Cooling plate sensor failure
16 P9 Current sensor failure
17 PA Restart memory failure
18 F1 Compressor drive module failure
19 F2 PFC module failure
20 F3 Compressor start failure
21 F4 Compressor running failure
22 F5 Inverter board over current protection
23 F6 Inverter board overheat protection
24 F7 Current protection
25 F8 Cooling plate overheat protection
26 F9 Fan motor failure
27 Fb Power filter plate - no power protection
28 FA PFC module over current protection
When e heat pump displays ese error codes
please contact your installer for advice�
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Calorex i-Pac inverter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Calorex i-Pac inverter in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info