784879
32
Zoom out
Zoom in
Previous page
1/44
Next page
Tahatian
Page 29
electrIcal reQuIrementS
IMPORTANT
: Fill the spa with water before turning on the power.
Your CALDERA spa has been carefully designed to give you
maximum safety against electrical shock. Connecting the spa to an
improperly wired circuit will negate many of the spa’s safety features.
Improper wiring may also cause electrocution, risk of fire, and other
risks of injuries. Please read and follow the electrical installation
requirements and instructions for your specific spa model completely!
All CALDERA spa models, are equipped with a power indicator
(CALDERA Logo orange light) which, in addition to showing the spa
has power to it, has a diagnostic function as well. It will begin blinking
if the heater high-limit thermostat has tripped. If the power indicator
light is blinking, follow the instructions in the Troubleshooting section
to identify and correct the cause. The power indicator will stop blinking
once the problem has been corrected. The Power and Ready indicator
lights on the control panel also provide the same diagnostic function.
220 - 240 VOLT PERMANENTLY
CONNECTED
CALDERA spas must be wired in accordance with all applicable
National and Local Electrical Codes. All electrical work should be done
by an experienced, licensed electrician. We recommend the use of
appropriate electrical conduit, fittings, and wire for all circuits.
The CANTABRIA, GENEVA, NIAGARA & TAHITIAN spas require a
dual electrical service using a 16 & 25 amp breaker and wired per the
illustration found on the next page. Additionally, one main disconnect
switch with at least 3 mm separation between contacts must be used
for all electrical circuits to the spa.
NOTE: The CANTABRIA will require an additional 16 amp breaker
in order to operate the heater and the Lounge seat (jet pump 3) at the
same time. Without the additional 16 amp breaker, the heater will NOT
operate while the jets in the lounge (jet pump 3) are on.
Mount the subpanel according to local codes, but not closer than
1.5 meters (5 feet) away. Your spa must be supplied by a ground
fault circuit interrupter - residual current device (RCD) - with a
tripping rating not exceeding 30 mA in an electrical subpanel.
Open spa using Door Panel Removal instructions.
Insert power wires into spa from either side towards the bottom front,
you will find a plastic cap attached to spa.
Once your spa has been filled with water, turn it on and test all of
the circuit breakers.
IMPORTANT: If both breakers immediately trip, verify that the wires are
correctly connected. Each breaker should be tested prior to each use.
Here’s how:
1. Push the “TEST” button on each GFCI breaker, and observe it
click OFF.
2. Wait 30 seconds, then push the breaker switch to the OFF (down)
position (to ensure that it has completely disengaged), then push
the breaker switch to the ON (up) position. If you don't wait 30
seconds, the spa’s power indicator may continue to blink – try
again.
If any of the GFCI breakers fails to operate in this manner, your spa
may have an electrical malfunction, and you may be at risk of electrical
shock. Turn off all circuits and do not use the spa until the problem has
been corrected by an authorized service agent.
WARNING: Removing, or bypassing any GFCI breaker will result
in an unsafe spa and will void the spa’s warranty.
7
2
3
4
5
6
8
1
EQUIPMENT COMPARTMENT
The illustration below is to be used as a reference only (your spa may look different). The equipment compartment is located behind the front panel of the
spa below the Main Control Panel.
1. Jet pump*
2. EnergyPro
heater
3. ENERGY PRO Circulation Pump
4. Advent
Control Box
5. MONARCH Ozone Generator
6. Bonding terminal
7. Bluetooth Music (optional)
8. Subwoofer (optional)
1
Electrical Requirements
* There are 3 jet pumps located in the Cantabria equipment compartment, only 2 are shown in illustration above.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caldera Utopia serie - 2017 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caldera Utopia serie - 2017 in the language / languages: English as an attachment in your email.

The manual is 6.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caldera Utopia serie - 2017

Caldera Utopia serie - 2017 User Manual - German - 44 pages

Caldera Utopia serie - 2017 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info