DRAINING YOUR SPA
1. Turn off all GFCI breakers in sub-panel, or main electrical panel.
2. Locate the main drain valve (bottom front) for the spa. Pull on
handle (Figure 1, pliers may
be used to pull handle) until
you reach the mid position
then rotate handle slightly to
fully extended drain tube (drain
cap and 1” of the drain tube
is exposed) (Figure 2) then
remove the drain cap
(Figure 3).
NOTE: Do not remove drain
cap in mid position. Attach
the garden hose to the end
of the drain (to avoid flooding
of the foundation surrounding
the spa) making sure not to
push the drain tube inward.
Route the outlet of the hose to an
appropriate draining area.
NOTE: Spa water with a high
sanitizer level may harm plants
and grass.
3. Push the garden hose and drain
tube half-way back towards the
spa (Figure 4) which will start the
gravitational flow. Drain tube
must be in the mid position for
the spa to drain.
IMPORTANT: All models will
drain almost completely through
the drain valve. Equipment such
as the jet pump and heating
system may not completely
drain. Any water remaining within the plumbing or equipment after
draining will only need to be removed if the spa is being winterized.
4. After your spa is empty, clean the shell and filter cartridge.
5. Pull and remove garden hose, replace drain cap and push drain
tube back into spa as seen in Figure 1.
6. Follow the “START-UP PROCEDURES” to refill your spa.
PREVENTION OF FREEZING
Your spa has been designed and engineered for year-round use in
any climate. In some areas, extremely cold temperatures (below -12°C)
(10°F) combined with strong wind, may cause partial freezing of the jet
pump, even though the water inside the spa remains at the selected
temperature. The energy efficiency of the spa may also decrease during
these cold periods, as the heater will cycle more frequently. As an
additional precaution against partial freezing of some of the components,
the equipment compartment can be insulated with an insulating kit (P/N
31399) available from your local dealer. This insulating kit will also help
to maximize the spa’s energy efficiency.
NOTE: When warmer weather returns (approx. 16°-21°C) (60°-70°F),
the insulating kit must be removed to prevent overheating of the jet
pump.
WINTERIZING YOUR SPA
If you leave the spa unused for a long period of time in severely cold
weather, you should drain the spa and winterize it to avoid accidental
freezing due to a power or equipment failure.
DANGER: Use only Propylene Glycol as your anti-freeze (available
at most RV or marine supply stores). This is non-toxic. Never use an
automobile anti-freeze (Ethylene Glycol) since it is toxic!
WARNING: Failure to follow these instructions correctly can lead to
freeze damage not covered by warranty. It is strongly recommended
that you contact your local dealer to perform this service.
1. Drain your spa following the Draining Your Spa section in the
owners manual.
2. Remove the filter cartridge, clean and store in a dry place.
IMPORTANT: These additional instructions must be utilized
when draining and winterizing your spa in climates where the
temperature falls below 0°C (32°F). A 20 liter combination (vacuum/
blower) wet/dry shop vac must be used to effectively remove water
that is trapped inside the plumbing lines.
3. Attach the vacuum hose to the vacuum side of the shop vac.
Vacuum all openings and orifices as follows:
a. Jet openings: start with the jets at the top and move
downward (if suction is coming from another jet, block off the
other jet using a large rag – this will help pull out the water that
is trapped deeper inside the main line).
b. Filter suction fittings and filter compartment.
c. Main drain outlet (it may be necessary to cover the drain grate
tightly with a rag when vacuuming the main drain to ensure
water is drawn completely from the internal plumbing system).
4. Thoroughly dry the spa shell with a clean towel.
5. Remove pump door first. Once door is removed unscrew the pump
drain plugs located on the front of the pump housing. Allow all
water to drain out. Place the drain plugs in a ziplock bag and store
near the pumps. Replace the drain plugs on Start-up.
6. Unscrew the pump unions and allow the water to drain. Loosen
and remove hose attached to circulation pump to allow any
remaining water from heater and spa to drain out. Replace
circulation pump hose once water is drained. NOTE: Tighten the
pump unions prior to filling the spa.
7. Replace the main drain cap.
8. Using a long-extension funnel, pour anti-freeze into all standpipes,
filter suction fittings, jet orifices and water feature orifices. Also,
add anti-freeze to the FROG canister. Add enough anti-freeze to
ensure adequate protection – in many cases, you will see the liquid
in the orifice, or coming out of another location.
CAUTION: Use only Propylene Glycol as your anti-freeze. This is
non-toxic. Never use an automobile anti-freeze (Ethylene Glycol)
since it is toxic!
9. Close the spa cover and fasten the cover tie downs. Cover the spa
cover with two pieces of plywood to evenly distribute the weight of
snow and ice. Secure a plastic sheet, or tarp, over the spa cover
and plywood.
10. Replace the equipment access door, if removed.
OPENING INSTRUCTIONS:
1. Remove plywood and plastic sheet. Open the spa cover by
unfastening the cover tie downs.
2. Follow the Start-up Procedures in the Getting Started section of
the Owners Manual. Do not install filters to prevent them from
exposure to the anti-freeze.
Figure 1
Handle
Figure 2
Drain Cap
with
Handle
Figure 3
Drain
Tube
Garden
Hose
Figure 4
Spa Care and Maintenance
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caldera Utopia serie - 2017 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caldera Utopia serie - 2017 in the language / languages: English as an attachment in your email.

The manual is 6.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caldera Utopia serie - 2017

Caldera Utopia serie - 2017 User Manual - German - 44 pages

Caldera Utopia serie - 2017 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info