Page 6 Getting Started
WATERFALL VALVE
The SALINA, MAKENA, MARTINIQUE,
SEYCHELLES & REUNION spas are equipped
with a cascading waterfall feature. It is activated by
pressing the "JETS" button and turning the valve
located on the front interior wall counterclockwise.
The flow is regulated by turning the waterfall valve
to the desired position.
AIR CONTROLS
Each jet system has its own air
control. These allow you to change
the power of the jets by regulating the
amount of air that is mixed with the
water coming out of the jets.
QUICK START-UP INSTRUCTIONS
BEFORE YOU FILL YOUR SPA
Make sure your spa has been properly installed per all local codes, this
includes the location of the spa, the foundation of the spa as well as
the electrical installation of the spa. Installation instructions in the form
of a Pre-Delivery Instruction booklet can be obtained from either your
CALDERA dealer or online.
DO:
Know which water treatment system you will be using and make sure
you have necessary chemicals available. Read all of the instructions
that come with the system.
Have FRESHWATER 5-way Test Strips Available.
Have FRESHWATER Salt Test Strips Available if using the Salt system.
Have pH/Alkalinity Up & Down available.
Know the "Hardness" of your water, contact your dealer to help you
with this information. See Water Quality and Maintenance for more
information.
IMPORTANT: The spa can be filled with “softened” water as long as
the calcium hardness parameters (pg. 2) are maintained.
Purchase the Clean Screen pre-filter to remove unwanted
contaminants from the tap water. This is recommended, not required.
DON'T:
Power up the spa until it has been filled with water! Power to the
spa automatically activates critical components within the spa, such
as controls, heater, circulation pump, and other systems. If power
is supplied to these components prior to the spa being filled, the
components will be damaged, and this may result in a non-warranty
component failure.
Fill the spa with hot water or cold water with the cold water temperature
below 10º C (50º F)! Tripping of the high-limit thermostat may result
causing your spa to stop functioning.
START-UP
Your CALDERA spa has been thoroughly tested during the
manufacturing process to ensure reliability and long-term customer
satisfaction. A small amount of water may have remained in the
plumbing after testing and, as a result, may have spotted the spa shell
or the spa siding prior to delivery. Before filling the spa, wipe the spa
shell clean with a soft rag. The following instructions must be read and
followed exactly to ensure a successful start-up or refill.
CAUTIONS
Do NOT fill the spa with hot water, as tripping of the high-limit
thermostat may result.
DO NOT CONNECT POWER TO AN EMPTY SPA. Power to the
spa automatically activates critical components within the spa, such
as controls, heater, and other systems. If power is supplied to these
components prior to the spa being filled, the components will be
damaged, and this may result in a non-warranty component failure.
DO NOT use your spa after filling until all of the steps listed below are
completed.
DO NOT add chlorine if treating your spa with polyhexamethylene
biguanide (Biguanide, PHMB, eg. BaquaSpa
®) sanitizer.
Before filling your spa for the first time, remove the equipment
compartment door and check to ensure that the unions on either side
of the pump(s) and heater are hand-tight.
Door Panel Removal - see inside back cover:
a. Remove the 2 screws on the bottom of each corner.
b. Find notches in bottom of panel, place fingers on one side
and center notch. Slightly pull on bottom side panel to release 1st
clip. Move over to other side and center notch and pull on bottom
to release 2nd clip, then lower and remove panel.
1. CLOSE DRAIN, remove the filter compartment cover, skimmer
basket, weir, and filter. Fill your spa through the filter compartment
using the CLEANSCREEN pre-filter that attaches to your garden
hose. The water level of your spa should be maintained at a level
2.5 cm above the highest jet in the spa. Reinstall the filter and then
the skimmer basket, and weir once the spa is filled.
2. AFTER THE SPA HAS BEEN FILLED with water and the
equipment compartment door is secured, power must be applied
to the spa.
FIRST activate power to the subpanel from the main house
panel.
NEXT open the door of the electrical subpanel and reset the RCD
breaker.
FINALLY, close and secure the subpanel door.
3. TO CHECK THE OPERATION OF THE JET SYSTEM and to
purge any remaining air from the heating system complete the
following steps:
Press the soft button next to Jet Max to place both jet pumps on
High.
Once the jet system is fully operational (as indicated by strong,
non-surging jets), priming of the spa is complete
To turn off the jets, press
the soft button next to All Off on the
home screen
to turn all functions off simultaneously
If you do not feel a steady stream of water from your jets,
refer to the instructions for priming the pump in the SPA
TROUBLESHOOTING section.
IMPORTANT: Be sure that the diverter is in the middle position.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caldera Paradise - serie 2022 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caldera Paradise - serie 2022 in the language / languages: English as an attachment in your email.

The manual is 6.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caldera Paradise - serie 2022

Caldera Paradise - serie 2022 User Manual - German - 44 pages

Caldera Paradise - serie 2022 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info