697447
63
Zoom out
Zoom in
Previous page
1/72
Next page
2
Details about the MCM10 module
MCM10
63
System version 2:
Modulating 0 - 10 V controller, regulates acc. to
output
In conjunction with a building management system with
0 - 10 V interface, the total output of the cascade can be
selected as a control variable. This setting is made via a
jumper (Æ fig. 4).
Fig. 4 Setting via jumper
VT Flow temperature
P Output in % of rated cascade output
Fig. 5 Correlation between input voltage and output
P Output in % of rated cascade output
U Input voltage
System version 3:
Modulating 0 - 10 V controller, regulates to flow
temperature
In conjunction with a building management system with
0 - 10 V interface, the flow temperature can be selected
as a control variable. This setting is made via a jumper
(Æ fig. 4).
Fig. 6 Correlation between input voltage and flow
temperature
VT Flow temperature
U Input voltage
System version 4:
Heating control with ON/OFF contact
In conjunction with a control unit with ON/OFF contact,
the MCM10 module regulates the cascade output in
accordance with the contact closure respectively up to
maximum output, by starting one boiler after another.
When the contact opens all boilers are shut down
simultaneously.
The ON/OFF contact of the heating controller must be
zero volt.
2.7.8 Connection of additional modules in case of
heating controllers with 2-wire BUS control
Any other modules that may be installed, such as WM10
and MM10 modules (Æ fig. 3, [21], page 59), must be
connected to the heating controller BUS (parallel to
terminal J on the MCM10 module).
To prevent contact problems at the terminals of the
MCM10 master module, we recommend the use of a
junction box (Æ fig. 3, [20], page 59).
7 746 800 090-13.1O
VT[ C]
P[%]
0246810
6 720 617 648-09.1TD
0
30
50
70
90
U [V DC]
P [%]
90
75
60
45
30
15
0
0246810
7 746 800 090-08.1O
U [V DC]
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus MCM10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus MCM10 in the language / languages: English as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info