Logano plus GB402 – 6 720 804 428 (2012/09)
48
B 6A 577 No flame within
the safety time.
Ionisation current
within the safety time
<1.A.
Gas supply pressure too low. Notify gas supplier if the supply
pressure is too low.
The gas governor is not adjusted
to the required gas volume.
Install gas governor that is
adjusted to the required gas
volume or, if necessary, notify
gas supplier.
Inadequately sized gas line cross-
sections (min. cross-section of
the gas supply pipe).
Install adequately sized gas
lines.
Air in the gas line. Purge the gas line.
Excessively high flue system
backpressure through
unfavourable layout (too many
diversions; cross-section
inadequate or too long; horizontal
sections too long).
Size and route the flue system
correctly.
Ignition/ionisation electrode
contaminated.
Clean or replace ignition/
ionisation electrode.
Check cabling between the SAFe
and the ionisation electrode for
contact separation, breaks and
damage.
Make the contacts correctly.
Replace cable if required.
Check electrode gaps and
ignition/ionisation electrode for
damage.
Align burner rod or electrode.
Replace faulty electrode.
Check cabling between the
ignition transformer and ignition
electrode for contact separation
(on electrode and transformer),
breaks and damage.
Make the contacts correctly.
Replace cable if required.
SAFe burner control unit faulty. Replace the SAFe.
Ignition transformer faulty (no or
delayed ignition spark, "hard
start").
Replace the ignition
transformer.
V 6L 561 "Power up"
5 times (power
interruption
during burner
start).
The burner control unit
was switched off 5
times during the burner
start.
Check the 230 V power supply to
the control unit.
Reset burner control unit.
Remedy problem with the
power supply.
B 7A 550 Undervoltage. The mains voltage is
too low.
The power supply must not fall
below 195 V.
Ensure the correct power
supply.
B 7A 551 Voltage
interruption.
There has been a brief
power failure.
Check the power cable for
possible loose contacts.
Check the wiring and correct
contacts of the mains plug at the
MC10 or SAFe.
Remedy any contact problems.
B 7P 549 The safety chain
has opened.
The continuity of the
external components
tied into the MC10
safety chain has been
interrupted.
Check the continuity of the
components.
If required, replace faulty
components.
Type
1)
Display
code
Fault code Cause Description Test procedure/cause Correction
Tab. 22 Fault displays
1) V = locking; B = blocking
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logano plus GB402 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logano plus GB402 in the language / languages: English as an attachment in your email.

The manual is 5,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logano plus GB402

Buderus Logano plus GB402 User Manual - English - 20 pages

Buderus Logano plus GB402 User Manual - German - 2 pages

Buderus Logano plus GB402 Installation Guide - Dutch - 60 pages

Buderus Logano plus GB402 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info