BE-1204B-BC • BE-1204C-BC • BE-1206B-BC 12-5
Chapter 12 Troubleshooting
Symptom Measures
The needle bar case lock error
occurs.
Is the INDEX motor rotating?
If not, refer to the block diagram showing the cable connections and
check to see if connection from the INDEX motor to the main PCB
is proper.
Check the resistance values of pins 1 and 3 and pins 4 and 6 at the
connector section of the INDEX motor. The normal resistance
value is approximately 6.6.
If it is not normal, replace the INDEX motor with a new one. Also
replace the drive PCB with a new one.
Manually turn the color change pulley.
If it is abnormally heavy, adjust the color change mechanism and
the needle cap case.
Replace the needle bar position sensor with a new one.
Replace the I/O PCB 0 with a new one.
X-axis or Y-axis home position
detection error occurs.
Was the XY carriage moving?
If so, refer to the block diagram showing the cable connections and
check to see if connection from the X and Y area sensor to the drive
PCB is proper.
Was the XY motor rotating?
If so, check the XY carriage mechanism.
If the XY motor is not rotating, refer to the cable connection block
diagram and check to see if connection from the XY motor to the drive
PCB is proper.
The thread breakage error frequently
occurs although thread is not broken.
Enter the CASE test mode and turn the thread breakage sensor pulley
corresponding to each needle bar of the head with which this error
occurs while switching the needle bar from number 1 in ascending
order and check to see that the red LED on the head blinks.
If there is no problem, lower the thread breakage sensitivity value of
the machine controller. (The standard value is 0.)
Check connection from the thread breakage sensor PCB to the thread
tension base PCB if it does not blink.
Replace the thread breakage sensor PCB with a new one.
The X-axis motor connector
connection error occurs.
Refer to the block diagram showing the cable connections and check
the connection from the two X motors (one X motors in four head
models) on the left and right to the main PCB.
The main shaft motor lock error
occurs.
Enter the encoder signal mode and manually turn the main shaft pulley.
If it is abnormally heavy, the main shaft mechanism is faulty.
Does the main shaft motor rotate at all when the error occurs?
If it does not rotate at all, check fuse F1, F2 and F3 on the power
supply PCB in the control box. Refer to the block diagram
showing the cable connections and check to see if connection from
the main shaft motor to the drive PCB is proper.
Manually turn the main shaft pulley in the encoder signal test mode
and check to see if the stop position signal and encoder signal are
proper.
If either of the signals does not change, refer to the block diagram
showing the cable connections and check to see if connection from
the encoder and stop position sensor to the power supply PCB is
proper.
253


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brother BE-1204B-BC - PC control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brother BE-1204B-BC - PC control in the language / languages: English as an attachment in your email.

The manual is 7,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info