6 Replacing the Filter Cartridge
!
Caution: During replacement, carefully examine all dismantled parts! Faulty parts must be
exchanged and dirty parts should be cleaned. Read the operating and safety information (Chapter 3)
prior to replacement. After the product has been stored and transported at temperatures below 0°C,
it must be stored with the original packaging open for at least 24 hours before commissioning at the
ambient temperatures for operation stated in Chapter 12.
Filter systems without a measuring and display unit
The fi lter cartridge must be replaced after 6–12 months and no later than 12 months after commis-
sioning regardless of the level of exhaustion of the fi lter system. If the capacity of the fi lter cartridge
has already been exhausted (Chapter 7), it must be replaced earlier.
Filter systems with a measuring and display unit
The fi lter cartridge must be replaced no later than 12 months after commissioning, irrespective of
the level of exhaustion of the fi lter system. If the capacity of the fi lter cartridge has already been
exhausted (Chapter 7), it must be replaced earlier.
If the cartridge is already exhausted, the capacity is indicated as being negative by fl ashing. No bars
are shown in the display.
If the monthly limit for the cartridge has been exceeded, this is indicated by the date fl ashing.
Resetting the display unit
To operate the display unit, it must be removed from the connecting fi ttings.
Slide the display housing up approx. 10 mm and pull off the display unit. The display unit is operated
using a button on the back of the display unit.
If this button is pressed (> 10 seconds), the data set on initial
installation will be accepted again, and the capacity, bypass
setting and input date are all updated.
Note: This automatically sets the monthly limit to 12 months.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode
without accepting amended parameters.
Insert the display unit from the front at a height of approx. 10 mm and slide down. The loops on the
display part must be inserted in the grooves on the measuring head.
6.1 Removing the Filter Cartridge
Switch off power supply to the terminal device (remove plug).
Close inlet valve
7
at inlet hose
6
.
Place the fl ushing hose in a bucket and remove pressure from the fi lter system by opening the
ush valve. Catch the escaping water in a bucket.
Note: If the escaping water is more than 1 litre, the inlet valve
7
is not completely closed or is
blocked with scale.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY 1200 Steam at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY 1200 Steam in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info