497163
26
Zoom out
Zoom in
Previous page
1/142
Next page
24
Carbonate Hardness
The units of carbonate hardness can be set as required to German °dH (= display setting °KH),
English (°e = Clark) (= display setting °EH), French (°f) (= display setting °FH), American (grains
per gallon) (= display setting gpg) or international hardness values (mg/l CaCO
3
) (= display setting
mg/L).
If the setting for the type of hardness (= unit) is changed while the fi lter is operating, the values that
were set originally are converted automatically.
Bar chart
Representation of the remaining capacity using bar charts. After installation of a new fi lter system or
after a fi lter change, the symbolised fi lter cartridge is completely fi lled with 10 bars.
Bypass proportion in percentage
The by-pass proportion is defi ned as the proportion of decarbonised water in the total amount of
ltrate and is indicated as a percentage.
Flow symbol
When water is removed via the fi lter system, a graphic wave is shown on the display.
Available remaining capacity of the fi lter cartridge
The remaining capacity of the fi lter cartridge is shown in litres or in US gallons, depending on which
has been selected.
When water is removed, it counts backwards in 1 litre or 1 US gallon stages. If the cartridge is
already exhausted, the capacity is indicated as being negative by fl ashing.
With a remaining capacity of 20% the last two bars in the bar chart start to fl ash.
With a remaining capacity of 10% the last bar in the bar chart fl ashes with the two change
arrows.
From a remaining capacity of 0% the negative bars and the change arrows fl ash alternately with
the remaining capacity shown in negative.
Date Field: Installation or
last fi lter change date
Local Carbonate
Hardness Set
Type/
By-Pass Proportion
Bar Display
Available residual
capacity in litres
Change arrow
If the monthly limit has been reached up to a month before expiry of the set time limit, it is signalled
by the date fi eld fl ashing.
If the monthly limit is 100% reached, it is signalled by alternate fl ashing of the date fi eld and the
change arrows.
If the remaining capacity and the monthly limit are exceeded, the negative remaining capacity and
the date fi eld fl ash alternately with the change arrows.
Date of the fi lter commissioning or last fi lter cartridge change
The date of fi lter commissioning or last fi lter cartridge change is indicated as follows:
Example: 28/10/09
28 Day, here the 28th day
10 Month, here October
09 Year, here 2009
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY 1200 Steam at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY 1200 Steam in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info